检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:郑小斌[1] 柯以铨[1] 张世忠[1] 姜晓丹[1] 张旺明[1] 徐江平[2] 程玉芳[2] 袁欣[2]
机构地区:[1]南方医科大学珠江医院神经外科,广东神经外科研究所,广东省脑功能修复与再生重点实验室,广州510280 [2]南方医科大学神经药理学实验室,广州510515
出 处:《中华神经医学杂志》2012年第6期594-599,共6页Chinese Journal of Neuromedicine
基 金:国家自然科学基金(81172416/H1618);广东省科学计划项目(20098030801375);国家临床重点专科建设项目
摘 要:目的探讨清醒状态下丘脑底核(STN)长期在体多通道单细胞放电记录新技术。方法采用自行设计的集束式微电极阵列记录STN单细胞放电情况。设计主要由3部分构成:(1)29号皮下注射用不锈钢管为引导管固定电极丝,并作为脑组织接地电极;(2)5根20μm铂铱合金丝作为记录电极,1根50.8μm不锈钢合金丝作为局部参考电极,电极尖端呈“路标手”样排列,聚乙二醇固定;(3)带有螺丝旋紧的连接器减少实验动物自由活动带来的信号伪迹。将这种电极用于6只正常清醒大鼠STN单细胞放电记录,评价术后5周内的STN单细胞放电单位的记录稳定性。结果术中记录到27个STN放电单位,70.4%(19/27)存活超过2d:5周内记录到9个新生放电单位。术后峰峰波幅与时间之间无显著线性相关性(r=-0.047,P=0.655);并且信噪比维持稳定,其与峰峰波幅间存在显著线性相关(r=0.934,P=0.000)。电极植入3周,仍有超过50%的细胞保留率。相同神经元75%波形相似系数大于0.90。结论本研究设计的微电极阵列在记录活动状态下STN单细胞放电时.波形特征稳定.细胞保留率理想,适用于慢性清醒状态在体STN多通道单细胞放电的电生理记录.Objective To introduce a bundled microelectrode array of chronic in vivo single-unit recording in subthalamic nucleus (STN) of freely behaving rats. Methods STN single cell discharge was recorded by a self-designed bundled microelectrode array. Our microelectrode array design consisted of 3 parts: (1) a 29-guage stainless steel tube was served as a guide tube to facilitate the brain penetration ofmicrowire tips, and as a ground electrode of the brain tissues as well. (2) Five 20μm platiniridium wires were used as recording electrodes and a 50.8 μm stainless steel wire with 1 mm bare tip was employed as local potential reference; all the above resembled a guiding-hand-shaped arrangement in microwire tips, and was fixed by tiny plot of carbowax moreover. (3) A male connector with end screw receptors was employed to make the array connection more stable so as to minimize the movement artifacts; six normal rats were implanted with this kind of electrode arrays, and the stability of STN single-unit recording was evaluated in the following 5 weeks. Results Twenty-seven firing units were captured during operation, of which 70.4% (19/27) survived more than 2 d, and 9 new units were acquired within 5 weeks. No significant linear correlation of peak-to-peak amplitude was noted between each 2 different recording sections (Pearson r=-0.047, P=-0.655), and whilst signal-to-noise ratio was stable with significant correlation to peak-to-peak amplitude (r=0.934, P=0.000). More than half of the initial acquired STN units retained more than 3 weeks. And there were more than 75% r values of waveform similarities large than 0.90 of the same units across different periods. Conclusion This methodology may be appreciated for STN long-term single-unit recording with stable recording quality and favorable cell retained rate.
分 类 号:R742.5[医药卫生—神经病学与精神病学]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.222