A twin-channel difference model for cross-calibration of thermal infrared band  被引量:2

A twin-channel difference model for cross-calibration of thermal infrared band

在线阅读下载全文

作  者:LI JiaGuo GU XingFa YU Tao LI XiaoYing GAO HaiLiang LIU Li XU Hui 

机构地区:[1]State Key Laboratory of Remote Sensing Science,Institute of Remote Sensing Applications,Chinese Academy of Sciences,Beijing 100101,China

出  处:《Science China(Technological Sciences)》2012年第7期2048-2056,共9页中国科学(技术科学英文版)

基  金:supported by the National Natural Science Foundation of China (Grant No. 40971227);the International Corporation Program of Science and Technology Ministry of China (Grant No. 2010DFA21880)

摘  要:Based on the conduction and transformation of the thermal infrared radiative transfer equation of water target,a twinchannel difference model(DM) was proposed to improve the calibration precision by conquering the limitation that the atmospheric condition when image is acquiring cannot be truly obtained in the traditional radiometric simulation calibration method.The analysis of surface,atmosphere and top-of-atmosphere(TOA) radiative energy decomposition demonstrated that the apparent TOA radiance of the uncalibrated channel is the differential combination of two reference channels.The DM avoids impacts from atmospheric temperature and density.The only impact is from water vapor(WV) content.Based on the fitting error analysis of 742 mid-latitude atmospheric profiles(column WV content:0-5×10 3 atm cm) selected from TIGR database,the DM is insensitive to WV content.The maximum error is less than 0.2 K when the view zenith angels(VZAs) of reference channels and uncalibrated channel are less than 30.The error becomes 0.3 K when VZAs range from 30 to 40 and 0.6 K when VZAs are in 40-50.Because the uncertainty increases when VZAs are larger than 50,the best range of VZAs is 30-50.The vicarious calibration results at Lake Qinghai field indicated that the calibration precision of the DM cross-calibration by using MODIS bands 31 and 32 as reference channels to calibrate IRS band 08 is similar to that of vicarious calibration.Therefore,the DM is a reliable alternative tool for sensor on-orbit calibration and validation with high precision and frequency.

关 键 词:remote sensing CROSS-CALIBRATION difference model IRS MODIS 

分 类 号:TP342.1[自动化与计算机技术—计算机系统结构] S152.7[自动化与计算机技术—计算机科学与技术]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象