Zywave波前像差仪在近视屈光不正测量中的应用  

Application of Zywave wavefront analyzer in measurement of myopic ametropia

在线阅读下载全文

作  者:张卫霞 曾照年 唐秀侠 孙宏霞 李洪润[2] 

机构地区:[1]武警河南省总队医院眼科,河南省郑州市450052 [2]解放军第425医院眼科,海南省三亚市572012

出  处:《眼科新进展》2012年第7期665-667,共3页Recent Advances in Ophthalmology

摘  要:目的评价Zywave波前像差仪在近视屈光不正测量中的临床应用价值。方法选择2010年8月至2011年2月在本院拟行近视屈光不正矫正术的患者197例(394眼),根据患者在睫状肌麻痹前电脑验光的球镜度数分成一般度数组(<-6.00D)、高度数组(-6.00~-9.00D)和超高度数组(>-9.00D)3组。对同一眼的球镜度数、散光度数和散光轴向分别用电脑验光仪、Zywave波前像差仪和综合验光仪三种检查方法测量,所得结果行统计学分析。结果一般度数组:电脑验光、Zywave波前像差仪、综合验光仪3种方法测得的球镜度数分别为(-4.05±1.41)D、(-3.90±1.44)D、(-4.06±1.33)D,散光度数分别为(-1.74±0.88)D、(-1.59±0.71)D、(-1.53±0.69)D,散光轴向分别为(85.98±43.88)°、(99.18±45.21)°、(94.02±45.98)°,3种方法测量结果之间比较,差异均无统计学意义(均为P>0.05)。高度数组:电脑验光、Zywave波前像差仪和综合验光仪3种方法测得的球镜度数分别为(-7.51±0.83)D、(-7.80±0.76)D、(-7.54±0.79)D,散光度数分别为(-1.64±1.17)D、(-1.92±1.01)D、(-1.74±1.00)D,散光轴向分别为(79.90±43.15)°、(96.07±50.56)°、(81.31±46.98)°,3种方法测量结果之间比较,差异均无统计学意义(均为P>0.05)。超高度数组:电脑验光、Zywave波前像差仪、综合验光仪3种方法测得的球镜度数分别为(-12.01±1.81)D、(-11.78±1.81)D、(-12.60±1.78)D,散光度数分别为(-1.56±0.88)D、(-1.85±1.01)D、(-2.16±0.80)D,散光轴向分别为(93.80±34.23)°、(106.70±35.55)°、(95.20±29.47)°,3种方法测量结果之间比较,球镜度数及散光轴向差异均无统计学意义(均为P>0.05),而散光度数间差异有统计学意义(P<0.05)。结论 Zywave波前像差仪测量近视屈光不正有较高的准确性,在临床应用中有一定的参考价值。Objective To evaluate the value of Zywave wavefront analyzer in measurement of myopic ametropia. Methods One hundred and ninety-seven patients (394 eyes) with myopic ametropia in our hospital from August 2010 to February 2011 were divided into 3 groups based on the spherical degree before cycloplegia by comput- er optometry: General myopia group ( 〈 - 6.00 D), high myopia group ( from - 6.00 D to - 9.00 D) and hypermyopia group ( 〉 - 9.00 D). The spherical degree, astigmatism degree and axis in the same eye were measured by computer optometry,Zywave wave- front analyzer, integrated refractometer, the results were statistical analyzed. Results In general myopia group, the spherical degrees measured by computer optometry, Zy- wave wavefront analyzer,integrated refractometer were ( - 4.05 ± 1.41 ) D, ( - 3.9± 1.44) D and ( - 4.06± 1.33 ) D, astigmatism degrees were ( - 1.7±0.88 ) D, ( - 1.59±0.71)D and ( - 1.53 ±0.69) D,and the axis of astigmatism were (85.98 ±43.88)°, (99.18±45.21 )° and (94.02 ± 45.98 )°~ ,there was no statistical difference among three methods ( all P 〉 0.05 ). In high myopia group, the spherical degrees measured by com- puter optometry, Zywave wavefront analyzer, integrated refractometer were ( - 7.51 ± 0.83 ) D, ( - 7.80 ± 0.76) D and ( - 7.54± 0.79) D, astigmatism degrees were ( - 1.64 ± 1.17)D,( -1.92 ±1.01)D and ( -1.74 ± 1.00)D,and the axis of astigmatism were (79.90 ±43. 15)°, (96.07 +50.56)° and (81.31±46.98)°,there was no statistical difference among three methods ( all P 〉 0.05 ). In hypermyopia group, the spherical degrees measured by computer optometry, Zywave wavefront analyzer, integrated refrac- tometer were ( - 12.01 ± 1.81 ) D, ( - 11.78 ± 1.81 ) D and ( - 12.60± 1.78 ) D, astigma- tism degrees were ( - 1.56 ± 0.88) D, ( - 1.85 ± 1.01 ) D and ( - 2.16 ± 0.80) D, and the axis of astigmatism were (93.80 ± 34.23 )°, �

关 键 词:波前像差仪 电脑验光 综合验光仪 近视 屈光不正 

分 类 号:R737.9[医药卫生—肿瘤]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象