检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:洪侃[1,2] 郁志明[3] 石维[2] 刘志华[1] 许宇静[2] 卞坤娟[2] 黄玉政[4] 徐明[4]
机构地区:[1]苏州大学附属第一医院心内科,江苏苏州215006 [2]南京医科大学附属无锡人民医院内分泌科,江苏无锡214023 [3]南京医科大学附属无锡人民医院心内科,江苏无锡214023 [4]江苏省血吸虫病防治研究所,江苏无锡214064
出 处:《南京医科大学学报(自然科学版)》2012年第7期1033-1037,共5页Journal of Nanjing Medical University(Natural Sciences)
摘 要:目的 :利用弱阳离子磁珠纯化(magnetic beads based weak cation exchange chromatography,MB-WCX)系统结合基质辅助激光解析电离-飞行时间质谱(matrix-assisted laser desorption/ionization time-of-flight mass spectrometry,MALDI-TOF-MS)的方法获取糖尿病肾病(diabetic nephropathy,DN)的尿小分子差异多肽谱。方法:按Mogensen标准,根据3 d平均微量白蛋白尿排泄率,将68例2型糖尿病患者分组,其中正常蛋白尿(DM1)组24例,微量白蛋白(DM2)组22例,大量蛋白(DM3)组22例;健康对照(C)组20例。DM1及DM2组肾小球率过滤(glomerular filtration rate,GFR)均>90 ml/(min.1.73 m2),DM3组GFR为60~89 ml/(min.1.73 m2)。采用MB-WCX试剂盒富集尿多肽,再经MALDI-TOF-MS技术,采集尿液多肽谱,应用ClinProtTM软件进行生物学比较分析。结果:质荷比<12 000时,DM1组与C组相比,有15个蛋白质峰差异有统计学意义(P<0.01)。DM2组与C组相比,有1个蛋白质峰差异有统计学意义(P=0.029 8)。DM3组与C组相比,有10个蛋白质峰差异有统计学意义(P<0.01)。结论:MB-WCX系统联合MALDI-TOF-MS蛋白质检测技术,能够获得健康人及DN患者尿液小分子多肽谱,为进一步从中寻找早期筛查的标志物提供基础。Objective:To detect urinary polypeptide patterns in stages of the type 2 diabetic nephropathy (DN) in order to screen and find out the potential biomarkers. Methods:A total of 68 urine samples from type 2 diabetic patients with normoalbuminuria (DMI,n = 24),microalbuminuria (DM2,n = 22)and maeroalbuminuria (DM3,rt = 22),and healthy controls (C,n = 20) were condensed by magnetic beads based weak cation exchange chromatography (MB-WCX),and analyzed by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS). ClinProtTM software was used to profile and screen the polypeptide patterns in urine of the patients. Results:When the relative molecular mass 〈 12 000, there were significant differences in 15 protein peaks between group DM1 and group C(P 〈 0.01 ). There was one protein peak of significantly low expression in the group DM2,when compared to group C (P = 0.029 8). And there were significant differences in 10 protein peaks between group DM3 and group C (P 〈 0.01 ). Conclusion: MB-WCX coupled to MALDI-TOF-MS is a fast, convenient and high throughput analyzing method capable of screening some relatively specific and potential biomarkers from the urine of DN with different stages.
关 键 词:磁珠分离 基质辅助激光解吸电离-飞行时间质谱 糖尿病肾病 尿液 多肽
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:18.190.156.78