布洛芬原料药中残留有机溶剂和微量金属杂质的检测研究  被引量:12

Study on determination of residual solvents and trace metal impurities in ibuprofen

在线阅读下载全文

作  者:王梅 郑晖 

机构地区:[1]山东省淄博市药品检验所,淄博255086

出  处:《药物分析杂志》2012年第7期1209-1213,共5页Chinese Journal of Pharmaceutical Analysis

摘  要:目的:针对布洛芬的生产工艺,建立原料药中残留有机溶剂(二氯甲烷、乙醇)和微量金属杂质(铝、钴、镍)的检测方法。方法:残留溶剂采用顶空毛细管气相色谱法,使用DB-624毛细管色谱柱(30 m×0.53 mm,膜厚3.0μm),载气为氮气,检测器采用FID,柱温采用程序升温,顶空平衡温度80℃,平衡时间60 min,以N,N-二甲基甲酰胺(DMF)为溶剂;金属杂质采用微波消解-石墨炉原子吸收法测定,通过石墨炉程序升温进行测定。结果:在残留溶剂的测定中,两待测组分之间的分离度为6.3,在测定浓度范围内r分别为0.9999和0.9998,检测限分别为0.2μg.g-1和2μg.g-1,加样回收率分别为101.1%和101.0%。在3种金属杂质的测定中,检测限分别为5 ng.g-1、5 ng.g-1和10 ng.g-1;在测定浓度范围内,r分别为0.9996,0.9993,0.9998;3种待测元素的加样回收率均大于90.0%;结论:测定方法准确可靠,灵敏度高,适用于布洛芬原料药中残留溶剂和微量金属杂质的分析检测。Objective:Based on the manufacturing process of ibuprofen, to establish an evaluation method for de- termination of residual solvents (methylene chloride and ethanol) and trace metal impurities (aluminium, cobalt, nickel) contained in API ( active pharmaceutical ingredient) of ibuprofen. Methods: DB - 624 capillary column ( 30 m ×0. 53 mm × 3.0 μm ) was adopted, the temperature was warmed according to instrument's procedure, FID was selected as detector. Headspace equilibrium temperature was 80 ℃, equilibrium time was 60 minutes, and N, N- dimethylacetamide was applied as the solvent; microwave digestion -graphite furnace atomic absorption spec- trometry was adopted for determine metal impurity through raising temperature by graphite furnace procedure. Results: For residual solvent determination, good linear responses were obtained from the two residual solvents in their respective concentration ranges ( r = 0. 9998, 0. 9999) , furthermore, the limits of detection were 0.2 and 2 μg. g^-1 respectively. The average recoveries of three concentration levels were 101.0% and 101.1% respectively. For metal impurity determination, the limits of detection were 5 ng . g^-1 5 ng . g^-1 and 10 ng . g^-1respectively, and r = 0. 9996, 0. 9993 and 0. 9998 in their respective concentration ranges . The recoveries of three metal elements based on three concentrations were all above 90. 0%. Conclusions: The developed method is simple, sensitive, and accurate for the residual solvents and trace metal impurities analysis of ibuprofen API.

关 键 词:气相色谱法 顶空采样 残留溶剂 微波消解 石墨炉原子吸收分光光度法 布洛芬 金属杂质    

分 类 号:R917[医药卫生—药物分析学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象