检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:刘祖强[1] 刘开钳[1] 白洁冰[1] 邵鹏[1] 李红华[1]
机构地区:[1]广东省深圳市宝安区疾病预防控制中心理化检验科,518101
出 处:《职业与健康》2012年第16期1977-1978,1981,共3页Occupation and Health
摘 要:目的使用直接测汞仪,建立测定食品中汞含量的新方法。方法采用热分解齐化原子吸收法,直接测定食品中汞的含量。结果回归方程为A=0.043 0 Hg+0.0160相关系数为R=0.999 5,线性范围为0.00~10.00 ng,精密度为0.62%~17.2%,回收率为85.8%~105.8%,检出限为0.03 ngHg。结论该方法操作简便快速,各项指标均可满足食品中汞的测定要求。[Objective]To establish a new method for mercury determination in food by direct mercury analyzer.[Methods]The mercury content in food was determined by thermal decomposition/amalgamation atomic absorption spectrophotometry.[Results] The regression equation: A=0.043 0 Hg+0.016 0;correlation coefficient : R=0.999 5;the linear range was 0.00-10.00 ng;precision was 0.62%-17.2 %;recoveries were 85.8%-105.8%;detection limit was 0.03 ngHg.[Conclusion]The method is simple,rapid.The indicators can meet the requirements of determination of mercury in food.
关 键 词:直接测汞仪 食品中汞含量 热分解齐化原子吸收法
分 类 号:R155.5[医药卫生—营养与食品卫生学]