二茂铁桥联聚倍半硅氧烷修饰电极测定抗坏血酸  被引量:1

Detection of Ascorbic Acid by Ferrocene-Bridged Polysilsesquioxanes Modified Glassy Carbon Electrode

在线阅读下载全文

作  者:胡印 陈婧[2] 高春光[2] 

机构地区:[1]山西省大同市天镇县第一中学,山西大同038200 [2]山西大学化学化工学院,山西太原030006

出  处:《化学与生物工程》2012年第11期83-86,共4页Chemistry & Bioengineering

基  金:国家自然科学基金资助项目(20573071);山西省自然科学基金资助项目(20041017)

摘  要:以1,1′-双[2-(三乙氧基硅基)乙基]二茂铁单体及正硅酸乙酯为前驱物,经溶胶-凝胶过程制备了二茂铁功能化的聚倍半硅氧烷修饰电极,并将该修饰电极用于抗坏血酸(H2A)的电催化氧化测定。在pH=8.0的0.1mol.L-1 NaClO4-H3PO4缓冲溶液中,氧化峰峰电流和H2A浓度呈良好线性关系,动态线性范围2.0×10-5~1.0×10-3 mol.L-1,相关系数为0.994,检测限为1.3×10-5 mol.L-1。Ferrocene-bridged polysilsesquioxanes modified glassy carbon electrode (BTEF/TEOS/GCE) was prepared via depositing the sol-gel formed by co-hydrolysis of 1,1′-bis[(2-triethoxylsilyl)ethyl]ferrocene (BTEF) and tetraethoxysilane (TEOS). The BTEF/TEOS/GCE showed a better electrocatalytic activity in the oxidation of ascorbic acid (H2A). The catalytic peak current had a linear relationship with H2 A concentration in the range o{ 2.0×10-5 -1.0×10-3 mol·L-1 with the linear correlation coefficient of 0. 994 and the detection limit was 1.3×10-5 mol×L-1.

关 键 词:二茂铁 聚倍半硅氧烷 修饰电极 电催化 抗坏血酸 

分 类 号:O657.15[理学—分析化学]

 