机构地区:[1]苏州大学医学部药学院,江苏苏州215123 [2]司法部司法鉴定科学技术研究所 上海市法医学重点实验室,上海200063
出 处:《法医学杂志》2012年第6期422-425,共4页Journal of Forensic Medicine
基 金:上海市法医学重点实验室资助项目(12DZ2271500)
摘 要:目的建立血液、尿液中乙腈的顶空气相色谱检测方法。方法以异丙醇为内标,采用DB—ALCl(30m×320μm×1.8μm)和DB—ALC2(30m×320μm×1.2μm)双毛细管色谱柱对血液、尿液中的乙腈进行测定。结果血液、尿液中乙腈的检出限均为0.5μg/mL,线性范围为5~1000μg/mL(r=0.999);加标回收率为9312%~98.0%,日内及日间精密度≤3.7%。结论该方法适用于血液、尿液中乙睛的检测。Objective To establish the method for measurement of acetonitrile in blood and urine by head-space gas chromatography. Methods DB-ALCI (30m×320 μm×1.8 μm) and DB-ALC2 (30m×320 μm× 1.2 μm) capillary column were used to measure the acetonitrile in blood and urine with the isopropanol as internal standard reference. Results The limits of detection of acetonitrile in both blood and urine were 0.5μg/mL, with a linear range of 5-1 000 μg/mL (r=0.999).The accuracy of this method was 93.2%-98.0%. The RSD for the intra-day and inter-day were less than 3.7%. Conclusion The method is capable for measurement analysis of acetonitrile in blood and urine.
分 类 号:R123.1[医药卫生—环境卫生学]