RTVue傅里叶光学相干断层扫描仪测量角膜参数的重复性和准确性评价  被引量:3

Repeatability and accuracy of corneal parameters measured by RTVue Fourier-domain optical coherence topography

在线阅读下载全文

作  者:华焱军[1] 黄锦海[1] 潘超[1] 王勤美[1] 

机构地区:[1]温州医学院附属眼视光医院眼视光学院浙江省眼科医院,325027

出  处:《中华实验眼科杂志》2013年第2期177-181,共5页Chinese Journal Of Experimental Ophthalmology

基  金:卫生部科技教育司卫生行业科研专项资金资助项目(200802114)

摘  要:背景角膜各参数(如曲率、厚度等)对于诊断角膜源性疾病、角膜接触镜的验配及角膜屈光手术至关重要。目的研究RTVue傅里叶光学相干断层扫描仪(FD—OCT)评估角膜各参数的重复性与准确性,为FD—OCT的临床应用提供参考依据。方法本研究为前瞻性研究。接受准分子激光角膜原位磨镶术(LASIK)术前检查者43例77眼,屈光度为-1.25—-10.00D,散光度〈2D。使用RTVueFD—OCT测量角膜中央3miTl直径范围内前表面曲率半径Ranterior、后表面曲率半径Rposterier、角膜后前表面曲率半径之比Rposterion/Ranterier、中央角膜厚度(CCT)、通过厚透镜公式获得角膜总屈光力Knet、模拟角膜屈光力SimK、角膜前表面中央直径3mm范围内屈光力Kanterior、角膜后表面中央直径3mm范围内屈光力Kposierior,及基于Placido环原理的Topolyzer获得的角膜屈光力K。,每只受试眼连续测量3次。采用变异系数(CV)、CronbachAlpha系数及组内相关系数(ICC)评估重复性,重复测量方差分析比较SimK与Knet、Knet与Km、SimK与Km之间的差异性,Pearson相关分析SimK与Knet、Knet,与Km、SimK与Km之间的相关性,Bland—Altman分析SimK与Knet、Knet与Km、SimK与K。之间的一致性。结果Ranterior,Rposterior、Rposterior/Ranterior、Kanterior、Kposterior SimK、Knet和CCT分别为(7.691±0.302)mm、(6.532±0.276)mill、0.849±0.014、(48.97±1.92)D、(-6.13±0.26)D、(43.95±1.72)D、(42.95±1.68)D和(545.20±35.04)mm,各参数的CV均〈1%,CronbachAlpha系数均〉O.9;Rposterior/Ranterier的ICC为0.802,其余参数ICC均〉O.9。SimK比Km大(0.27+0.34)D,Knet比Km小(0.73±0.37)D,SimK比Knet大(1.01±0.11)D,差异均有统计学意义(P〈O.001)。SimK与K。、K。与K。、SimK与K。均呈正相关(r=0.981、0.976、0.998,P〈0.001)。Bland—Altman分析�Background Corneal parameters (such as curvature, thickness, etc) are essential to the diagnosis of corneal related diseases, contact lenses fitting and corneal refractive surgery. Objective The aim of this study was to assess the repeatability and accuracy of corneal parameters obtained by RTVue Fourier-domain optical coherence topography ( FD-OCT). Methods In this prospective study, 77 eyes of 43 subjects with the refraction from -1.25 D to -10.00 D and astigmatism 〈2 D were enrolled in keratorefractive surgery center, Eye Hospital of Wenzhou Medical College. The anterior and posterior corneal curvature in 3 mm central zone ( R nor and Rpo,oror) ,the ratio of posterior and anterior curvature (Rpote,~or/Rrior), corneal central thickness (CCT), total corneal power( Kno, ) , the simulated corneal power (SlinK) , the anterior and posterior corneal power ( Kanterlo, Kpo ) were measured by FD-OCT. Corneal power ( Km ) was obtained by Topolyzer topography based on Placido ring. Three consecutive scans were acquired in every tested eye. Repeatability of FD-OCT measurement was assessed using the coefficient of variation ( CV), Cronbach Alpha and intra-elass correlation coefficient (ICC). Repeated measure ANOVA was used to analyze the differences among SimK, Koo, and K,,. Pearson correlation analysis was used to analysis the correlation between SimK and K o,, K e, and Km , SimK and K. The agreement between SimK and K,, K o, and Km,SimK and K was assessed by Bland-Altman plots analysis. All the subjects understood the purpose of this investigation and written informed consent was obtained prior to the medical examination. Results The Ranterior, Rposterior , 1~posterior/Ranterior, K ,~rior, Kpo~,~rio~ , SimK, K,ot and CCT were ( 7. 691 ±0. 302) ram, ( 6. 532-±0. 276) ram, 0. 849±0. 014, (48.97±1.92) D, (-6. 13±0.26)D,(43.95±1.72) D, (42.95±1.68)D and (545.20± 35.04) μm, respectively. The CV of all parameters was less than 1% . The Cronbach A

关 键 词:光学相干断层扫描 Topolyzer 角膜曲率 角膜厚度 生物测量 重复性 一致性 

分 类 号:R77[医药卫生—眼科]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象