Portable Analyzer for Rapid Analysis of Total Protein, Fat and Lactose Contents in Raw Milk Measured by Non-dispersive Short-wave Near-infrared Spectrometry  被引量:6

Portable Analyzer for Rapid Analysis of Total Protein, Fat and Lactose Contents in Raw Milk Measured by Non-dispersive Short-wave Near-infrared Spectrometry

在线阅读下载全文

作  者:FENG Xu-dong SU Rui XU Nan WANG Xing-hua YU Ai-min ZHANG Han-qi CAO Yan-bo 

机构地区:[1]College of Chemistry, Jilin University, Changchun 130012, P. R. China

出  处:《Chemical Research in Chinese Universities》2013年第1期15-19,共5页高等学校化学研究(英文版)

摘  要:A novel portable analyzer for raw milk quality control during the material purchase at dairy plants was developed, by which the percentages(mass fraction) of main components including total protein, fat, and lactose of an unhomogenized milk sample could be determinated in 1 min with the help of non-dispersive short-wave near-infrared (NDSWNIR) spectrometry in a wavelength range from 600 nm to 1100 nm and multivariate calibration. The analyzer was designed with a single-beam optical system, which comprised a temperature control module, a multi-channel narrow-band light source(16 wavelengths), a glass absorption cell with 15 mm sample thickness, a silicon photodiode detector, several compound lenses and a recorder module. A total of 80 raw milk samples were collected at a dairy farm twice a month for 4 months. The samples were scanned with a common UV-Vis-NIR spectrometer and analyzed according to China GB standard methods. The uninformative variables elimination(UVE) method was carried out on the spectrum data and the percentages of main components of all the samples to choose the peak emitting wavelength of each channel of the light source. Another 90 raw milk samples were collected from the same dairy farm thrice a month for 3 months. The samples were analyzed according to China GB standard methods and with the proposed analyzer. The percentages of the main components and the NDSWNIR absorption data of the samples were used for the construction and validation of the multivariate calibration model with partial least squares(PLS) method. The root-mean-square errors of prediction(RMSEP) of total protein, fat and lactose were 0.201, 0.172 and 0.247 and the coefficients of correlation(R) were 0.932, 0.981 and 0.933, respectively.A novel portable analyzer for raw milk quality control during the material purchase at dairy plants was developed, by which the percentages(mass fraction) of main components including total protein, fat, and lactose of an unhomogenized milk sample could be determinated in 1 min with the help of non-dispersive short-wave near-infrared (NDSWNIR) spectrometry in a wavelength range from 600 nm to 1100 nm and multivariate calibration. The analyzer was designed with a single-beam optical system, which comprised a temperature control module, a multi-channel narrow-band light source(16 wavelengths), a glass absorption cell with 15 mm sample thickness, a silicon photodiode detector, several compound lenses and a recorder module. A total of 80 raw milk samples were collected at a dairy farm twice a month for 4 months. The samples were scanned with a common UV-Vis-NIR spectrometer and analyzed according to China GB standard methods. The uninformative variables elimination(UVE) method was carried out on the spectrum data and the percentages of main components of all the samples to choose the peak emitting wavelength of each channel of the light source. Another 90 raw milk samples were collected from the same dairy farm thrice a month for 3 months. The samples were analyzed according to China GB standard methods and with the proposed analyzer. The percentages of the main components and the NDSWNIR absorption data of the samples were used for the construction and validation of the multivariate calibration model with partial least squares(PLS) method. The root-mean-square errors of prediction(RMSEP) of total protein, fat and lactose were 0.201, 0.172 and 0.247 and the coefficients of correlation(R) were 0.932, 0.981 and 0.933, respectively.

关 键 词:Portable analyzer Raw milk Non-dispersive short-wave near-infrared(NDSWNIR) spectrometry Multiva-riate calibration 

分 类 号:TS261.7[轻工技术与工程—发酵工程] S431.7[轻工技术与工程—食品科学与工程]

 