检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:陈小林[1] 袁国[1] 王昭东[1] 王国栋[1]
出 处:《东北大学学报(自然科学版)》2013年第2期227-230,共4页Journal of Northeastern University(Natural Science)
基 金:国家科技支撑计划项目(2012BAF04B01)
摘 要:为了升级改造某轧后冷却系统,成功将超快冷系统嵌入其中,并使之与原层流冷却系统有机结合,组成了新一代中厚板轧后冷却系统.针对原层流冷却一级系统的"黑箱"屏蔽现象,为了保持原层流冷却系统的独立性和完整性,在深入解析原层流冷却系统二级模型的基础上,提出基于冷却模式进行系统切换原则并采用"先进先出"的队列存储技术,实现了新增超快冷系统与原层流冷却系统的无缝衔接.现场应用表明,该新一代中厚板轧后冷却系统运行稳定.To upgrade a cooling system after rolling,ultra-fast cooling(UFC) and original acceleration cooling(ACC) systems were combined to form a new-generation plate cooling system after rolling(ADCOS-PM).Since the first level of the ACC system was shielded as a "black box",the mathematical model of the second level was analyzed in depth.Considering the independence and integrity of the original ACC system,the "first-in first-out" queue storage technology was proposed on the basis of the cooling mode switching principle.Using the proposed method,the seamless combination of the new-added UFC system and the primitive ACC control system was achieved.Furthermore,this new system was applied to the plate industry production successfully.