Screening for amblyopia among grade-1 students in primary school with uncorrected vision and stereopsis test in central China  被引量:6

Screening for amblyopia among grade-1 students in primary school with uncorrected vision and stereopsis test in central China

在线阅读下载全文

作  者:FU Jing LI Shi-ming LI Jin-ling LI Si-yuan LIU Luo-ru WANG Yang LI He ZHU Bi-dan JI Ya-zhou YANG Zhou LI Lei CHEN Wei WANG Ning-li 

机构地区:[1]Beijing Tongren tye Center, Beijing Tongren Hospital, CapitalMedical University Beijing Ophthalmology and Visual ScienceKey Laboratory, Beijing 100730, China [2]Anyang Eye Hospital, Anyang, Henan 455000, China [3]Department of Ophthalmology, Second Hospital Affiliated toHarbin Medical University, Harbin, Heilongjiang 150001, China

出  处:《Chinese Medical Journal》2013年第5期903-908,共6页中华医学杂志(英文版)

基  金:This study was supported by grants from the Major State Basic Research Development Program of China ("973" Program, No. 2011CB504601) and the Major International (Regional) Joint Research Project (No. 81120108807) of the National Natural Science Foundation of China.

摘  要:Background Screening for amblyopia at earliest is important for early treatment and better prognosis. This study aimed to evaluate the validity of uncorrected distant and near visual acuity (VA) and stereoacuity for screening amblyopia in grade-1 students in primary school in central China. Methods By stratified cluster sampling, 3112 grade-1 students from 11 Anyang primary schools were selected for the study. All the participants underwent uncorrected distant and near VA, stereopsis test, cycloplegic refraction, best corrected VA (BCVA), cover test, and ocular movement examination. VA was measured with a logarithm of the minimum angle of resolution (IogMAR) chart. Stereoacuity was measured with the Lang II stereo card and TNO test. Amblyopia was defined as the BCVA less than or equal to 0.1 IogMAR units of any eye in the absence of significant pathological abnormalities. The sensitivity, specificity, and 3ositive and negative predictive value of uncorrected VA and stereoacuity for amblyopia were analyzed. Results Out of the 3112 eligible students 2893 (92.96%) completed the examinations. The average age of the students was (7.10±0.41) years. Screened by distant VA with low cutoff (IogMAR 0.1), high cutoff (IogMAR 0.0), and near VA (IogMAR 0.0), 31.64%, 73.18%, and 50.23% students were abnormal, respectively. Screened by stereopsis test, only 4.69% students were abnormal. Diagnosed by a senior pediatric ophthalmologist, 61 students had amblyopia. The sensitivities of distant VA with low/high cutoff and near VA were 92.31%, 100%, and 80.77%, respectively, whereas that of stereoacuity by TNO test was 15.38%. Simultaneous testing of either two of the three tests improved the sensitivity. Conclusions Distant VA test of high cutoff alone displays a high sensitivity but a low specificity. Simultaneous testing of distant VA of low cutoff and stereoacuity is a better choice to balance between sensitivity and specificity.Background Screening for amblyopia at earliest is important for early treatment and better prognosis. This study aimed to evaluate the validity of uncorrected distant and near visual acuity (VA) and stereoacuity for screening amblyopia in grade-1 students in primary school in central China. Methods By stratified cluster sampling, 3112 grade-1 students from 11 Anyang primary schools were selected for the study. All the participants underwent uncorrected distant and near VA, stereopsis test, cycloplegic refraction, best corrected VA (BCVA), cover test, and ocular movement examination. VA was measured with a logarithm of the minimum angle of resolution (IogMAR) chart. Stereoacuity was measured with the Lang II stereo card and TNO test. Amblyopia was defined as the BCVA less than or equal to 0.1 IogMAR units of any eye in the absence of significant pathological abnormalities. The sensitivity, specificity, and 3ositive and negative predictive value of uncorrected VA and stereoacuity for amblyopia were analyzed. Results Out of the 3112 eligible students 2893 (92.96%) completed the examinations. The average age of the students was (7.10±0.41) years. Screened by distant VA with low cutoff (IogMAR 0.1), high cutoff (IogMAR 0.0), and near VA (IogMAR 0.0), 31.64%, 73.18%, and 50.23% students were abnormal, respectively. Screened by stereopsis test, only 4.69% students were abnormal. Diagnosed by a senior pediatric ophthalmologist, 61 students had amblyopia. The sensitivities of distant VA with low/high cutoff and near VA were 92.31%, 100%, and 80.77%, respectively, whereas that of stereoacuity by TNO test was 15.38%. Simultaneous testing of either two of the three tests improved the sensitivity. Conclusions Distant VA test of high cutoff alone displays a high sensitivity but a low specificity. Simultaneous testing of distant VA of low cutoff and stereoacuity is a better choice to balance between sensitivity and specificity.

关 键 词:AMBLYOPIA vision screening visual acuity steropsis test 

分 类 号:R777[医药卫生—眼科]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象