附加黏滞阻尼器结构附加等效阻尼比算法研究  被引量:14

Research on Calculation of Equivalent Damping Ratio of Structure with Viscous Dampers

在线阅读下载全文

作  者:胡岫岩[1] 任晓崧[1] 翁大根[1] 徐斌[2] 丁孙玮[2] 周红卫[2] 

机构地区:[1]同济大学土木工程防灾国家重点实验室,上海200092 [2]上海材料研究所,上海200437

出  处:《力学季刊》2013年第1期114-124,共11页Chinese Quarterly of Mechanics

基  金:上海市科学技术委员会基金资助(10DZ2252000);科技部国家重点实验室基础研究项目资助(SLDRCE10-D-01)

摘  要:本文基于应变能概念,从附加等效阻尼比计算的基本理论出发,结合国内外相关规范、导则及论文,讨论了几种计算附加非线性黏滞阻尼器建筑结构的附加等效阻尼比实用估计方法。以一个实际工程为算例,比较附加黏滞阻尼器结构和两种不同估计方法得到的附加等效阻尼比的阻尼结构在地震时程下的响应,验证了各方法计算结果满足工程精度情况。On the basis of the concept of strain-energy method, with the basic theories of calculation for e- quivalent damping and the combination of related codes, guide rules and papers of domestic and abroad, several practical methods were discussed which were used to estimate the additional damping of structure with nonlinear viscous dampers. Through a practical engineering project, the responses with viscous damper model and the one with additional damping ratio model were compared under earthquake time-hi- story, which verified that the results of the methods of calculation for equivalent damping ratio satisfy the engineering precision.

关 键 词:黏滞阻尼器 消能减震 等效阻尼比 