量热法SS-AlN太阳吸收涂层半球发射比测量装置  

AN APPARATUS FOR MEASURING HEMISPHERICAL EMITTANCE OF SS-AlN SOLAR ABSORBING COATINGS USING A CALORIMETRIC TECHNIQUE

在线阅读下载全文

作  者:周旭[1] 郭帅[1] 王双[1] 池华敬[1] 陈革[1] 章其初[1] 

机构地区:[1]皇明太阳能股份有限公司镀膜研发中心,德州253000

出  处:《太阳能学报》2013年第5期805-809,共5页Acta Energiae Solaris Sinica

摘  要:采用稳态量热法,研制了一台真空集热管内管外表面SS-AlN太阳吸收涂层半球发射比测量装置。集热管内置三段式加热器,采用直流电源给加热器供电,测量在恒定温度时主加热器的加热功率,计算得到该温度下吸收涂层的半球发射比。多次测量同一支SS-AlN集热管的选择性吸收涂层的80℃半球发射比εss-AlN(80℃)=0.0596±0.0004。另外,多次测量同一支Cu真空管的Cu涂层的半球发射比εCu(80℃)=0.0217±0.0002。采用该装置测量真空集热管的吸收涂层半球发射比,测量精度高。An apparatus for measuring hemispherical emittance of SS-A1N solar absorbing coatings using a calorim- etric technique has been laboratory-made. Three heaters, spaced by 3mm ceramic rings, heated with DC power supplies, were inserted inside the SS-A1N vacuum collector tube. Measuring the power dissipated in the central heater at the constant temperature for a vacuum solar collector tube, thus hemispherical emittance of the solar coat- ing on the outside surface of an inner tube may be calculated. The hemispherical emittance of the SS-A1N solar absorbing coating of a vacuum tube at 80℃ was measured for several times, the measured value of εss-AIN(80℃) is 0. 0596 ± 0. 0004. In addition, the hemispherical emittance of the copper coating of a vacuum tube at 80℃ was measured, the measured value of εCu(80℃) is 0. 0217± 0. 0002. The measured hemispherical emittance values with high precision have been achieved using this apparatus.

关 键 词:全玻璃真空集热管 稳态量热法 SS-AlN吸收涂层 半球发射比 

分 类 号:TB43[一般工业技术] TH73[机械工程—仪器科学与技术]

 