作 者:李端姣[1] 朱文俊[2] 王红斌[2] 胡岳[3]
机构地区:[1]广东电网公司,广州510060 [2]广东电网公司电力科学研究院,广州510080 [3]上海交通大学电气工程系,上海200240
出 处:《南方电网技术》2013年第2期91-95,共5页Southern Power System Technology
摘 要:针对已有的变电站全站局部放电检测方法仅能得到放电源的大致方向,无法区分局部放电类型和来源的问题,基于各种局部放电源所产生的超高频信号在时域与频率的不同特征,对连续采集存储的局部放电电磁波脉冲波形进行TRPD(time resolved peak display)时频分析和模糊聚类,分离出不同局部放电源或干扰所产生的放电信号,以实现放电源的准确定位,为后期局放类型的图谱特征识别奠定基础。现场测试证明了该方法的可行性。Aiming at the problems of existing method for the partial discharge (PD) detection of whole substation such as the PD source being not clear in its discharge type and location, and based on the time domain and frequency characteristics of UHF signals of various PD source, this paper does TRPD (time resolved peak display) frequency analysis and fuzzy cluster on the electromagnetic pulse waveforms that are continuously gathered and storaged to separate out the different discharge source or interference, locating accurately the discharge source, and thus providing a basis for the feature recognition of PD types. The feasibility of the proposed method is proved with the field tests results.
分 类 号:TM933[电气工程—电力电子与电力传动]