机构地区:[1]厦门大学附属福州第二医院眼科福州眼科医院,福州350007 [2]福建医科大学附属漳州市医院眼科漳州市眼科中心,漳州
出 处:《中华眼外伤职业眼病杂志》2013年第7期503-505,共3页Chinese Journal of Ocular Trauma and Occupational Eye Disease
摘 要:目的评价白内障手术中应用晶状体囊孔夹持固定人工晶状体的安全性和有效性。方法26例(27眼)白内障(包括老年性,先天性,外伤性,后发性和人工晶状体雨刷综合征)术中将人工晶状体光学部夹持固定在前囊或后囊孔,术后随访观察。结果随访3个月至2年,所有病例视轴清澈,人工晶状体固定良好,20眼(74.1%)最佳矫正视力在0.6以上。结论应用晶状体囊夹持固定人工晶状体,视力恢复好,人工晶状体稳定,并发症少。Objective To evaluate the safety and efficacy of intraocular lens (IOL) optic capture in capsular opening during catract surgery. Methods The capture of IOL optic through an anterior or poste- rior opening was performed in 26 cases (27 eyes) with senile cataract or congenital cataract, traumatic cata- ract, after cataract and IOL windshield wiper syndrome. All patients were foUowed-up after surgery. Results The visual axis remained clear and the IOL remained stable in all eyes in 3 months to 2 years follow-up. The best corrected visual acuity was 0.6 or better in 20 eyes (74.1% ). conclusion Capsular capture fix- ation of IOL provided good visual acuity, stable IOL, and less complication.