Artisan屈光性人工晶状体植入术后迟发性偏心观察  被引量:1

Clinical observation of late-onset decentration of Artisan Phakic intraocular lens for correction of high myopia

在线阅读下载全文

作  者:刘彩娟[1] 粱皓[1] 谭少健[1] 李霞[1] 

机构地区:[1]广西医科大学第一附属医院眼科,南宁530021

出  处:《中国实用眼科杂志》2013年第8期1025-1028,共4页Chinese Journal of Practical Ophthalmology

基  金:国家自然科学基金地区基金(81060076);教育部留学回国人员科研启动基金(2010-1561);广西医科大学自选课题(个性化植人人工晶状体治疗高度近视的研究);广西卫生厅自筹经费科研课题(Z2011344);广西研究生创新科研计划课题(2011105981002M225)

摘  要:目的分析Artisan屈光性人工晶状体(PIOL)植入术后远期随访人工晶状体在眼内位置及其偏心发生情况,以提高PIOL在眼内长期正位率及眼内稳定性。方法回顾性研究。高度近视患者行PIOL植入术后随访3年以上(平均4.5年)患者20例40只眼,按手术方法不同分为植入PIOL正位组和偏上组,对比术前术后视力、屈光度等临床指标,裂隙灯观察PIOL在前房位置,眼前段照相后测量PIOL在眼内位置,PIOL植入术后远期眼内偏心情况,及对角膜内皮细胞计数的影响。结果术后三年以上观察,34只眼裸眼视力t〉0.5,占87.18%。所有术眼(100%)最佳矫正视力I〉0.5。平均等效球镜屈光度为-0.34D(0.1.25D)。术中植入PIOL光学中心位于瞳孔正中位共30只眼平均观察4.8年(4~6.25年),随诊时16只眼发生PIOL下移,其中6只眼下移明显;平均下移(0.52±0.12)mm,10只眼发生轻度下移,平均下移(0.22±0.12)mm;3例4只眼发生PIOL不全脱位,其中3只眼发生于眼部外伤后,1只眼发生于分娩后;10只眼PIOL眼内位置无明显改变。术中植入PIOL光学中心位于瞳孔中央轻度偏上10只眼[PIOL光学中心位于瞳孔中央偏上方平均(0.38±0.10)mm,平均观察3.4年(3~4年],目前正位5只眼,保持轻度偏上5只眼,平均偏上(0.26±0.13)mm。角膜内皮细胞密度(ECD)在PIOL术后居中组、轻度偏上组和轻度偏下组安全稳定,明显下移及脱位患者ECD均有不同程度下降。结论PIOL植入术矫正高度近视效果良好,长期随访发现部分病例发生偏心,伴角膜内皮细胞不同程度的下降,术中固定PIOL稍微偏上可能可以对抗术后重力对PIOL的长期作用,从而提高PIOL的长期正位率,减少术后并发症的发生,提高手术安全性。Objective To analyze the occurrence of late-onset decentration of Artisan Phakic in- traocular lens (PIOL) implanted for correction of high myopia, to increase the long-term rate of nor- motopia and stability by modification of surgery skills. Methods A more than 3 years (average 4.5 years) retrospective follow-up study. Forty eyes of 20 patients underwent Artisan PIOL implantation for the correction of high myopia. The patients were divided into 2 group base on the difference of surgery method. Group 1 was PIOL implanted in the centre of pupil, Group 2 was PIOL implanted up the centre of pupil. The clinic data (included visual acuity, refraction, PIOL position) of the pre-operation and post-operation were compared, the occurrence of late-onset decentration and the in- fluence on endothelial cell density (ECD) were observed. Results After more than 3 years follow up, 34 eyes (87.18%) reached an uncorrected visual acuity (UCVA) of 0.5 or better, 40 eyes (100%) kept a best spectacle-corrected visual acuity (BSCVA) of 0.5 or better. The mean spherical equiva-lent (SE) was -0.34 diopters. There were 30 eyes PIOL had implanted in the center of pupil, more than half of eyes (16 eyes) were found down located position, obvious down located in 6 eyes (mean 0.52±0.12mm), and a little down located in 10 eyes (mean 0.22±0.12mm), in 4 eyes of 3 pa- tients PIOL dislocated form iris, In other 10 eyes PIOL located at the right position while fol- lowed-up (mean followed up 4.8 years). There were 10 eyes PIOL had implanted a little up located relative to the pupil (mean up the center 0.38±0.10mm), the PIOL at the right position in 5 eyes while another 5 eyes kept a relative up position of the pupil (mean up the center 0.26±0.13mm), mean followed up 3.4 years. In the group of PIOL located at the right position, a little upper loca tion and a little down location of pupil, the ECD showed safe and stabile, but in the eye PIOL clearly down located of pupil and dislocated

关 键 词:Artisan人工晶状体 高度近视 偏心 远期观察 

分 类 号:R776.1[医药卫生—眼科]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象