Fast determination of tobramycin by reversed-phase ion-pair high performance liquid chromatography with a refractive index detector  被引量:1

Fast determination of tobramycin by reversed-phase ion-pair high performance liquid chromatography with a refractive index detector

在线阅读下载全文

作  者:Liang ZHU Jingkang WANG 

机构地区:[1]Tianjin Key Laboratory of Marine Resources and Chemistry, College of Marine Science and Engineering, Yianjin University of Sciencc & Technology, Tianjin 300457, China [2]School of Chemical Engineering and Technology, Tianjin University, Tianjin 300072, China

出  处:《Frontiers of Chemical Science and Engineering》2013年第3期322-328,共7页化学科学与工程前沿(英文版)

摘  要:A simple and direct method without a deriva- tion step for routine analysis of tobramycin has been developed. This method used reversed-phase ion-pair high performance liquid chromatography (HPLC) with a refractive index (RI) detector and a C18 column which is stable at pH above 1.00. The presence of 4.50mg.mL ] trifluoroacetic acid (TFA) in the mobile phase improved the protonation of tobramycin and the formation of ionpairs, and thus reduced its hydrophility. This unique separation-detection combination showed good linearity with correlation coefficients 0.9996 in the concentration range of 0.25-2.50mg.mL 1. The quantitation limit and detection limit were determined to be 0.23 mg.mL ~ and 0.071 mg. mL ~, respectively. Tobramycin was recovered in 98.00%, 98.84% and 99.64% for tobramycin solutions at concentrations of 2.25 mg.mL^-1, 1.50mg.mL 1 and 0.75 mg.mL ', respectively. The relative standard deviations for six spiked samples ranged from 0.20% to 2.40%, indicating a good reproducibility of this method.A simple and direct method without a deriva- tion step for routine analysis of tobramycin has been developed. This method used reversed-phase ion-pair high performance liquid chromatography (HPLC) with a refractive index (RI) detector and a C18 column which is stable at pH above 1.00. The presence of 4.50mg.mL ] trifluoroacetic acid (TFA) in the mobile phase improved the protonation of tobramycin and the formation of ionpairs, and thus reduced its hydrophility. This unique separation-detection combination showed good linearity with correlation coefficients 0.9996 in the concentration range of 0.25-2.50mg.mL 1. The quantitation limit and detection limit were determined to be 0.23 mg.mL ~ and 0.071 mg. mL ~, respectively. Tobramycin was recovered in 98.00%, 98.84% and 99.64% for tobramycin solutions at concentrations of 2.25 mg.mL^-1, 1.50mg.mL 1 and 0.75 mg.mL ', respectively. The relative standard deviations for six spiked samples ranged from 0.20% to 2.40%, indicating a good reproducibility of this method.

关 键 词:TOBRAMYCIN AMINOGLYCOSIDE refractive index detector high-performance liquid chromatography ionpairing 

分 类 号:O657.34[理学—分析化学] TQ456.3[理学—化学]

 