Hybrid-Ⅲ50^(th)假人小腿受冲击位置和角度对腿部的伤害  被引量:6

Lower extremity injuries on a Hybrid- Ⅲ 50th dummy lower leg by impacted at different locations and angles

在线阅读下载全文

作  者:崔新康 马德仁 沈光勇 赵友梅 汪勇 

机构地区:[1]奇瑞股份有限公司汽车工程中心

出  处:《汽车安全与节能学报》2013年第4期334-338,共5页Journal of Automotive Safety and Energy

摘  要:正面碰撞的安全性对车辆前期开发非常重要。为研究前排假人腿部受伤害的影响因素,对假人进行摆锤冲击试验。Hybrid-III 50th男性假人安放在标定台座椅上,用5 kg的摆锤,以2.75 m/s速度,冲击假人左腿膝部或小腿,测量了大腿受力F、膝部位移D、上小腿绕X、Y轴的弯矩MX和MY、轴向压缩力FZ,以及胫骨指数(TI)。结果表明:当假人小腿中心与地面的夹角α为76°值时,F、D、MY发生突变。因此,为减少对小腿的伤害,在做车辆人机工程时,在大腿力容许范围内,应尽量使小腿碰撞位置靠近膝部,并使角α小于76°。Front impact safety is important to early develop vehicles. Pendulum impacts were performed on a dummy to investigate the influence factors to front-seated-dummy lower-leg injury. A Hybrid-Ⅲ 50th male dummy was seated on a chest calibration table. The dummy lower leg or knee was impacted by a 5-kg pendulum at 2.75 m/s. The upper-leg force F, the knee displacement D, the lower-leg-upper bending-moment Mx and My, the axial compression Fz, and the tibia-index (TI) during impacts were measured. The results show that the a of 76° is a special angle between the lower-leg center-line and horizontal ground, because the F, the D and My have abrupt changes when the impact occurres at 76°. Therefore, it will be considered that lower-leg impact-position should be close to the knee center with the upper-leg force within an accepted range at man-machine engineering design stage to reduce lower-leg injury. The angle a should be avoid being at the special angle of 76°.

关 键 词:汽车安全 碰撞 摆锤冲击试验 假人 撞击位置 膝部位移 大腿力 小腿 胫骨指数(TI) 

分 类 号:U461.91[机械工程—车辆工程]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象