作 者:王义海[1] 柔倩 张瑾熔[1] 伊斯刊达尔.阿不力米提 张玉晶[2] 吴恒[3] 黄晓辉[4]
机构地区:[1]新疆医科大学附属肿瘤医院胸腹放疗科,乌鲁木齐830011 [2]新疆医科大学附属肿瘤医院放疗中心,乌鲁木齐830011 [3]中山大学附属肿瘤医院,广州510060 [4]新疆大学信息科学与工程学院,乌鲁木齐830046
出 处:《新疆医科大学学报》2014年第1期97-100,共4页Journal of Xinjiang Medical University
基 金:新疆维吾尔自治区科技支疆项目(201191159)
摘 要:目的非小细胞肺癌患者通过图像引导放疗技术确定PTV外扩数值,与常规三维调强计划(CT-IMRT)进行剂量学比较研究。方法选取15例病理组织学确诊的非小细胞肿瘤患者,每周行1次肺部CBCT扫描,每次在放疗前、放疗后分别扫描,得到数据依据二参数法得到三维方向外扩距离,按照外扩距离数据重新勾画靶区并制定计划(CT-IGRT),并与原计划(CT-IMRT)的PTV、双肺、脊髓、心脏的受量、体积进行比较,差异行配对t检验;并依据LymanNTCP模型设计正常组织并发症概率(NTCP)程序,比较2种计划的肺组织NTCP,差异行非参数wilcoxson检验。结果校正后PTV外扩值较前减小。校正后肺平均剂量减小,2种计划有统计学差异。校正后随双肺受照体积增加,经CBCT校正后NTCP有下降趋势,V5、V10、V20、V30、V40、V50CT-IGRT比CT-IMRT明显减低(P均<0.05)。结论利用CBCT技术校正后可减小摆位误差,缩小PTV外扩数值,精确PTV外扩距离,减小双肺平均受照剂量,降低正常组织并发症概率。Objective To conduct a dosimetry comparison study of non-small cell lung cancer treated by image-guided radiotherapy technology, which determines PTV extended numerical and by regular 3D intensity-modulated plan (CT-IMRT). Methods 15 patients with non-small cell lung cancer were in the study. Two sets image were acquired every week before and after radiotherapy. The targeted volume was delineated, the plan (CT-IGRT) was made according to the extended distance data and compared with the former plan for dose-volume histogram of PTV, lung, spinal-cord and heart. The differences of two plans were analyzed by T sign rank test. The NTCP differences between the two plans were compared and analyzed by wilcoxson test. Results PTV extended values decreased obviously and the mean dose of lung redueed significantly after correction. The two plans had statistical difference. The double lung volume increased. NTCP had a downward trend after CBCT correction and VS, V10, V20, V30, V40, V50 reduced obviously (P 〈0.05). Conclusion The use of CBCT technology could reduce the beam position error after correction, narrow the PTV extended numerical and make PTV extended distance precise. The average illuminated double lung dose and the probability of normal tissue complication were reduced.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:18.222.108.223