VisuMax飞秒激光与SBK角膜板层刀制瓣安全性的对比研究  被引量:4

Comparison study on the safety of corneal flap made by VisuMax femtosecond laser and Moria One Use-Plus SBK microkeratome

在线阅读下载全文

作  者:胡裕坤[1] 李文静[1] 高晓唯[1] 郭云林[1] 董晶[1] 李晓红[1] 

机构地区:[1]解放军第474医院眼科医院屈光手术中心

出  处:《国际眼科杂志》2014年第2期251-254,共4页International Eye Science

摘  要:目的:评价VisuMax飞秒激光与Moria One Use-Plus SBK角膜板层刀制作超薄角膜瓣的舒适性与安全性。方法:回顾性病例系列研究。统计同期接受角膜屈光手术的778例1556眼(VisuMax飞秒激光组即A组384例768眼,SBK角膜板层刀组即B组394例788眼),对比术中舒适度评分、角膜瓣相关并发症、角膜瓣切口出血、球结膜下出血的发生率,评价两种方法的舒适性与安全性。结果:术中舒适度方面,感觉极不舒适,难以忍受者A组5例(1.3%),B组28例(7.1%);术中角膜瓣切口出血A组4眼(0.5%),B组74眼(9.4%);球结膜下出血A组18眼(2.3%),B组82眼(10.4%);角膜瓣边缘不齐A组0眼(0),B组94(11.9%);A组有4眼(0.5%)出现角膜瓣上皮部分剥脱,但未影响成功掀瓣及手术,A组有53眼(6.9%)发生角膜层间气泡(OBL)。两组无其它相关并发症。结论:两种方法安全可靠,均无严重影响术后视觉质量的角膜瓣相关并发症。AIM :To evaluate the comfort and security of ultra-thin corneal flap made by VisuMax femtosecond laser and Moria One Use-Plus SBK microkeratome. METHODS :This retrospective case series study included 1556 eyes of 778 consecutive patients. The eyes were assigned to two groups according to the method of the corneal flap made. VisuMax femtosecond laser group (group A) included 768 eyes of 384 consecutive patients. Moria One Use-Plus SBK microkeratome group (group B) included 788 eyes of 394 consecutive patients. We compared the comfort score in the surgery, the incidence of the corneal flap-related complications, the corneal flap incision bleeding and the subconjunctival hemorrhage, in order to evaluate the comfort and security between the VisuMax femtosecond laser and the Moria One Use-Plus SBK microkeratome. RESULTS:There were 5 patients (1.3%) feeling very uncomfortable and unbearable in group A while 28 patients (7.1%) feeling the same in group B. Four eyes (0.5%) occurred the intraoperative corneal flap incision bleeding in group A, while 74 eyes (9.4%) occurred in group B. The subconjunctival hemorrhage existed in 18 eyes (2. 3%) in group A while the same situation happened to 82 eyes (10.4%) in group B. No eyes (0%) occurred corneal flap edge missing in group A, but 94eyes (11.9%) occurred the symptom in group B. Four eyes (0.5%) of the corneal flap epithelial part exfoliated, however, that did not affect the successful flap surgery in group A. Fifty- three eyes (6. 9%) occurred Opaque Bubble Layer (OBL) in group A. There was no other corneal flap-related complication. CONCLUSION;The two methods are safe and reliable, and there are no corneal flap-related complications which seriously impact the visual quality after the surgery.

关 键 词:激光 外科皮瓣 角膜磨镶术 激光原位 飞秒激光 

分 类 号:R779.63[医药卫生—眼科]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象