检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]福建省漳州市医院烧伤整形科,363000 [2]福建省漳州市医院检验科,363000 [3]福建省漳州市医院血化室,363000
出 处:《中华整形外科杂志》2001年第1期37-39,共3页Chinese Journal of Plastic Surgery
摘 要:目的 探讨铜针通电治疗血管瘤并发急性血管内溶血的原因。方法 ①临床观察 1例巨大海绵状血管瘤两次铜针通电治疗均并发严重溶血的全过程。②体外实验分别将铜针、铁针和不锈钢针置于健康人枸橼酸抗凝血中 ,接 3~ 6V直流电 30min ,在通电前、中、后检测各标本血浆游离Hb值 ;推血片光镜下观察RBC形态。结果 临床病例两次铜针通电治疗均发生严重血管内溶血 ;体外实验通电后RBC变形破碎 ,血浆游离Hb明显升高。电压越高 ,通电时间越长 ,RBC破坏越严重。结论 铜针通电治疗巨大血管瘤可能并发严重的急性血管内溶血。电流对RBC的直接损伤是导致溶血的主要因素。Objective\ To study the pathogenesis of acute intravascular hemolysis following copper needle electrothrombosis for treating a huge cavernous hemangioma. Methods\ (1) The full course of severe intravascular hemolysis in a patient with huge cavemous hemangioma treated by copper needle electrontrombosis was observed.(2)In vitro experiment, a copper needle, an iron needle and a stainlss steel needle were put in citrated anticoagulant healthy blood specimens respectively. The needles were electrified with 3~6 voltages DC for 30 minutes. Then the free hemoglobin of the specimens was tested before, during and after electrfication. The red cell morphology was observed under a light microscope. Results\ Severe intravascular hemolysis occurred in twice treatments with copper needle electrothrombosis. In vitro experiment showed that erythroclasis occurred after needle electrifying with obvious increasing of free plasma hemoglobin of the specimens. The higher the voltage and the longer the electrification of the needle, the more severe the hemocytocatheresis. Conclusions\ Severe intravascular hemolysis may happen during copper needle electrothrombosis for treating huge cavernous hemangioma. Red blood cell injury directly caused by electrification is the main factor of intravascular hemolysis.\;
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.42