大型机组冗余灭磁回路及控制技术  

Redundant de-excitation circuit and control technology for large unit

在线阅读下载全文

作  者:李宇俊 张李军 王洋 

机构地区:[1]东方电机控制设备有限公司,四川德阳618000

出  处:《水电站机电技术》2014年第1期14-17,63,共4页Mechanical & Electrical Technique of Hydropower Station

摘  要:旨在针对一般可控硅跨接器耐电压等级不够高,导致跨接器接入耗能元件的灭磁方式存在灭磁可靠性不高的缺点,提供了一种基于耐高电压可控硅跨接器的冗余灭磁保护回路及其控制技术。理论和实践表明,该方案可以安全、可靠地将耗能元件接入灭磁回路,大大提高了事故状态下灭磁的可靠性,满足巨型机组的技术要求。The voltage resistance for the common controlled silicon is at a low level.Aiming at disadvantage of weak stability of the de-excitation when the jumper is joined with a dissipative cell,redundant de-excitation circuit protection and control technologies are proposed by using the controlled silicon jumper with high voltage resistance.The theory and application show that this method can safely and reliably join the dissipative cell to the de-excitation circuit,and greatly improve the reliability of the de-excitation in case of accident situation.Therefore,this method can satisfy technology demands for the giant unit.

关 键 词:耐高电压跨接器 冗余 灭磁 触发器 

分 类 号:TV734[水利工程—水利水电工程]

 