检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]上海市消防总队,上海200051 [2]奥雅纳工程咨询(上海)有限公司,上海200031
出 处:《消防科学与技术》2014年第4期441-444,共4页Fire Science and Technology
摘 要:介绍一种综合消防工程学、火灾动力学和风险评估理论的建筑整体火灾风险分析方法 FRAME。介绍其方法框架及算法,并以某地上商业项目的靠近下沉广场的一个防火区块为例,分析FRAME方法在火灾风险评估中的应用。该方法在基于建筑功能、活动和消防设计的基础上,既考虑实际火灾性能,亦充分体现处方式设计的规范要求,可以协助设计师在进行消防与生命安全设计之前发现消防设计的薄弱环节并采取有针对性的强化消防措施。A total fire risk analysis method called Fire Risk Anal- ysis Method for Engineering (FRAME) was introduced, which combined the concepts of fire protection engineering and fire dy- namics and the basic theories of risk evolution. The structure and algorithm of the method were introduced. Taking a fire dis- trict near the sunken plaza of a commercial building as an exam- pIe, the application of FRAME in fire risk analysis was intro- duced. In FRAME method, the building functions, activities and the fire protection design should be thoroughly reviewed and then the possible fire performance and the basic require- ments of codes should also be fully embodied. FRAME method can help the designer to realize the weakness of a specific build- ing and the strengthen measures and revision adopted in the preliminary design phase.
分 类 号:X913.4[环境科学与工程—安全科学] TU998.1[建筑科学—市政工程]