摘 要:将配电线路分为架空线路和电缆线路两大类,并建立精确、简化和近似3种线路模型。给出负荷不平衡线路伏安特性的计算方法,通过分析线路模型对电压不平衡度的影响,进而研究线路模型对配电网状态估计的影响。通过IEEE33节点系统对不同线路模型进行测试,得出结论:精确模型对实时量测的影响较小,对精度不高的伪量测影响较大;若要提高伪量测的精度,可采用简化模型。This paper divides power distribution lines into two classifications including overhead lines and cable lines and establishes three line models including precise line model,simplified line model and approximate line model.It provides calculation method for V-I characteristics of load unbalanced lines and studies impact on state estimation on distributed network of line modes by analyzing impact of line models on voltage unbalanced degree.Based on IEEE 33 node system,it proceeds testing for different line models and draws conclusions that the precise model has smaller impact on real-time metering while it may has more impact on false metering with low precision.In addition,it suggests to use simplified model to improve precision of false metering.
分 类 号:TM744[电气工程—电力系统及自动化]