检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:庄沛林[1] 叶剑涛[1] 黄卓珊[1] 余艳崧[1] 伍虹[1]
机构地区:[1]中山大学孙逸仙纪念医院口腔科,广州510120
出 处:《中华口腔医学研究杂志(电子版)》2014年第2期19-23,共5页Chinese Journal of Stomatological Research(Electronic Edition)
基 金:国家自然科学基金(81200825)
摘 要:目的评价K锉、Safesiders锉和HERO Shaper锉预备离体牙弯曲根管的成形效果。方法 60颗根管弯曲的离体下颌前磨牙随机分为3组,分别用K锉、Safesiders锉和HERO Shaper锉进行根管预备,根管预备前后分别往根管内注入复方泛影葡胺并拍摄X线片,分析根管预备后根管弯曲内外侧壁牙本质去除量、中心定位能力及根管直化角度。结果在根管弯曲内外侧壁所有观测点,Safesiders锉组和HERO Shaper锉组牙本质去除量均少于K锉组(P均>0.05)。Safesiders锉组牙本质去除量多于HERO Shaper锉组,但仅在根管弯曲内侧壁3和4 mm观测点处差异有统计学意义(3 mm:t=3.72,P<0.05;4 mm:t=7.62,P<0.05)。在距根尖孔5 mm以下观测点,Safesiders锉组和HERO Shaper锉组中心定位能力优于K锉组(1 mm:F=7.45,P<0.05;2 mm:F=10.20,P<0.05;3 mm:F=7.75,P<0.05;4 mm:F=23.45,P<0.05;5 mm:F=10.91,P<0.05);而在所有观测点上,Safesiders锉组与HERO Shaper锉组差异均无统计学意义(P均>0.05)。Safesiders锉组和HERO Shaper锉组根管直化角度均小于K锉组(F=58.95,P<0.05),但Safesiders锉组与HERO Shaper锉组间差异无统计学意义(P>0.05)。结论 K锉、Safesiders锉和HERO Shaper锉预备离体牙弯曲根管均有不同程度的根管偏移,其中Safesiders锉和HERO Shaper锉根管偏移较少,具有较好的根管成形效果。Objective To evaluate the shaping efficacy of K files , Safesiders files and HERO Shaper files in curved root canal preparation of human teeth in vitro. Methods Sixty mandibular premolars with curved root canal were divided into three groups randomly, and prepared by K files, Safesiders files and HERO Shaper files respectively. Compound meglumine diatrizoate was injected into root canals and X-ray graphs of teeth were taken before and after instrumentation . The amount of dentin removed from inner and outer walls , centering ability and degree of straightening of root canal after preparation were analyzed. Results Safesiders files and HERO Shaper files removed less dentin from inner and outer walls than K files at all measuring points (P〈0.05). Safesiders files group displayed more dentin removed than HERO Shaper files group, however, the differences were not statistically significant except for the 3 mm and 4 mm measuring points in inner walls (P〈0.05). Safesiders files group and HERO Shaper files group showed better centering ability than K files group at measuring points below 5 mm (P 〈 0.05), and differences between Safesiders files group and HERO Shaper files group was not statistically significant (P 〉 0.05). The use of K files resulted in more straightening of root canal after instrumentation compared to other instruments (P 〈 0.05), and the differences between Safesiders files group and HERO Shaper files group was not significant (P 〉 0.05). Conclusions K files, Safesiders files and HERO Shaper files caused transportation when preparing curved root canals . Safesiders files and HERO Shaper files showed less transportation and better shaping efficacy .
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.15