检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:郑美洁[1] 向垒[1,2] 李彦文[1,2] 莫测辉[1] 蔡全英[1] 黄献培[1,2] 吴小莲[1,2] 赵海明[1,2]
机构地区:[1]暨南大学环境工程系、广东省高校水土环境毒害性污染物防治与生物修复重点实验室,广州510632 [2]暨南大学生态学系,广州510632
出 处:《分析化学》2014年第5期735-740,共6页Chinese Journal of Analytical Chemistry
基 金:国家自然科学基金项目(Nos.41071211,41173101,41301337);教育部博士点基金项目(No.200805590005);广东省自然科学基金重点项目(No.2011020003196);广东省高校高层次人才项目资助~~
摘 要:建立了液液萃取-气相色谱/质谱同时测定水中3种典型季胺盐化合物十二烷基三甲基氯化铵(DTAC)、十六烷基三甲基溴化铵(CTAB)、双十二烷基二甲基氯化铵(DDAC)的分析方法。采用电子轰击(EI)-选择离子模式(SIM)进行定性与定量分析,DTAC和CTAB的特征离子为m/z 58,DDAC的特征离子为m/z 212。考察了萃取剂种类、萃取次数、pH值以及盐度对萃取效率的影响。以HCl及30%NaCl溶液调节水样pH值为1.5及盐度为3%,以5 mL三氯甲烷萃取2次,3种目标化合物的线性范围在0.01~2.0 mg/L之间,检出限LOD(S/N=3)为2.5~8.5μg/L。以此方法测定自来水、湖水、河水、选矿废水样品,3种目标化合物的含量在0.06~2.45 mg/L之间,不同加标水平(0.2,0.5和1.0 mg/L)回收率在65%~113%之间,相对标准偏差在3.8%~23.0%之间。An analytical method was developed for the simultaneous extraction and determination of three quatermary ammonium compouds ( QACs ) in water samples using liquid-liquid extraction and gaschromatography mass spectrometry. The qualitative and quantitative analysis of the three analytes ( dodecyltrimethylammonium chloride ( DTAC) , CTAB and didodecyl-dimethyl-ammonium chloride ( DDAC) was conducted by application of EI Mass spectra and selected ion monioring ( SIM) . Characteristic ion of the first two (DTAC, CTAB) and the latter was m/z 58, and the characteristic ion of DDAC was m/z 212. To achieve optimum extraction efficiency, several impact factors including different types of extractants, extraction times, pH value and salinity in water sample matrixs were investigated. In the optimized extraction conditions, pH and salinity of water sample was adjusted to 1 . 5 and 3% respectively using hydrochloric acid and sodium chloride , then the processed water sample was extracted by chloroform twice with 5 mL every time in a 125 mL separatory funnel. Good linear relationships of all the three analytes were obtained in the range of 0. 01-2. 0 mg/L. The limits of determination ( LOD, S/N=3 ) was 2. 5-8. 5 μg/L. The method was used to analyse real water samples collected from running water, lake water, river water and beneficiation water. Results of determination displayed the concerntrations of the three analytes in real water samples ranged from 0. 06 mg/L to 2. 45 mg/L, and their recoveries ranged from 65% to 113% with relative standard deviations (RSD) 3. 8%-23% in three different spiked concentrations (0. 2, 0. 5 and 1. 0 mg/L).
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.222