骨折区钉孔保护对预防锁定钢板断裂的有限元分析  被引量:2

Finite Element Analysis of Protecting the Screw Holes to Prevent the Locking Plate Broken

在线阅读下载全文

作  者:林振恩[1,2] 郑玉云[1,2] 李贵武[1,2] 谢丹[1,2] 张森[1,2] 

机构地区:[1]厦门大学附属福州第二医院 [2]福建省福州中西医结合医院,福州370007

出  处:《中国中医骨伤科杂志》2014年第7期7-8,共2页Chinese Journal of Traditional Medical Traumatology & Orthopedics

基  金:福州市科技计划项目(2012-S-155-9)

摘  要:目的:探讨锁定钢板的骨折区钉孔保护对预防钢板断裂的意义;方法:通过ANSYS软件建模,建立2种股骨远端骨折锁定钢板固定模型,骨折区1种有螺钉固定,1种无螺钉固定,计算2种模型的钢板、螺钉应力;结果:2种模型中,骨折区有螺钉固定的钢板应力明显减少;结论:运用锁定钢板治疗股骨远端骨折,建议钢板的骨折区置钉固定,对骨折和钢板保护有利。Objective:To investigate the significance of protecting the screw holes in prevention of plate broken. Method:Two kinds of locking plate fixation model of distal femoral fracture were established through ANSYS software. One has screw fixation in frac- ture area and the other has not. Then the stress of plate and screw was calculated in two models. Results:The stress of plate with screw fixation in fracture area reduced significantly than that of other one. Conclusions:Screw fixation in fracture area is favorable for protecting plate and fracture in the treatment of distal femoral fractures with locking plate.

关 键 词:股骨骨折 有限元 内固定失效 钢板断裂 