机构地区:[1]南京大学医学院临床学院(南京军区南京总医院)眼科,南京医学硕士研究生210002
出 处:《医学研究生学报》2014年第6期600-604,共5页Journal of Medical Postgraduates
基 金:国家自然科学基金(81270979)
摘 要:目的 Acrysof IQ Restor multifocal toric人工晶状体(intraocular len,IOL)是一种新型IOL,可在一次手术中实现老视和角膜散光的矫正。文章旨在评价白内障超声乳化联合Acrysof IQ Restor toric IOL植入术后患者的早期临床效果。方法对前来南京军区南京总医院行白内障超声乳化联合多焦点散光型IOL植入患者7例(9眼)进行分析,其术前散光均≥1.0 D。术后随访3个月,分别观察术前及术后1周、1个月、3个月裸眼远近视力、最佳矫正远近视力、等效球镜等效球镜、焦点深度、预计残余散光、术后残余散光及人工晶状体的稳定性、对比敏感度(contrast sensitivity,CS)及脱镜率等。结果术后3个月,裸眼远视力(logMAR)为0.07±0.10,最佳矫正远视力为0.02±0.11,裸眼近视力为0.12±0.06,最佳矫正近视力为0.08±0.07,等效球镜≤±0.5D者8眼(88.9%),焦点深度为(5.32±1.78)D。术后3个月全眼总散光(0.25±0.28)D,与术前(1.55±0.39)D相比,差异有统计学意义(P<0.05)。术后全眼总散光与术前预计残留散光(0.13±0.09)D接近,其差异无统计学意义(P>0.05)。术后3个月,IOL轴位平均偏离(3.11±1.61)°。术后3个月与术后1个月相比,眩光和无眩光时CS在中低频区(3、6、12cpd)的提高差异无统计学意义(P>0.05),而在高频区(18cpd)提高差异有统计学意义(P<0.05)。术后脱镜率为100%。结论 Acrysof IQ Restor toric多焦点散光型人工晶状体能为白内障患者提供满意的全程视力、视觉质量和脱镜率,可预测性好,并有良好的旋转稳定性。Objective Acrysof IQ Restor multifocal toric intraocular lens( IOL) is a new product,which allows a single surgical procedure for presbyopia correction and corneal astigmatism management.This study was to evaluate the early clinical effects of phacoemulsification cataract surgery with implantation of a diffractive multifocal toric IOL.Methods We retrospectively analyzed 7cases( 9 eyes) of corneal astigmatism ≥1.0 diopter( D) treated by phacoemulsification with implantation of an Acrysof IQ Restor toric IOL.The patients were followed up for 3 months for observation of uncorrected distance visual acuity( UDVA),best corrected distance visual acuity( CDVA),uncorrected near visual acuity( UNVA),best corrected near visual acuity( CNVA),spherical equivalent( SE) refraction,focal depth,residual astigmatism,rotational stability of the IOL,contrast sensitivity( CS),and spectacle independence preoperatively and at 1 week,1 month,and 3 months after operation.Results At 3 months after surgery,the UDVA( logMAR),CDVA,UNVA,and CNVA were 0.07 ± 0.10,0.02 ± 0.11,0.12 ± 0.06,and 0.08 ± 0.07,respectively,with an SE refraction within ± 0.50 D of the attempted spherical correction in 8eyes( 88.9%) and a focal depth of( 5.32 ± 1.78) D.The residual astigmatism at 3 months was significantly reduced as compared with the baseline( [0.25 ± 0.28]vs [1.55 ± 0.39] D,P &lt; 0.05),but showed no statistically significant differences from the preoperative anticipated residual astigmatism( P &gt; 0.05).At 3 months,the mean IOL axis rotation was( 3.11 ± 1.61) ° and CS was remarkably improved( P &lt; 0.05),while CS with or without glare was not significantly different from that at 1 month at all spatial frequencies( P &gt;0.05) except at 18.0 cpd( P &lt; 0.05).Conclusion Implantation of the Acrysof IQ Restor multifocal toric IOL provides excellent overall quality of vision,spectacle independence,visual quality,and rotational stability for patients with catar
关 键 词:多焦点散光型人工晶状体 离焦曲线 散光 对比敏感度
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...