湛江发电厂4号机抗燃油泵的振动测试与分析  被引量:1

Vibration measurement and analysis of Unit 4 fire-resistant oil pumps in Zhanjiang Power Plant

在线阅读下载全文

作  者:刘艳梅[1] 徐之昌[2] 薛宇伟[3] 

机构地区:[1]湛江发电厂,广东湛江524099 [2]广东省电力试验研究所,广东广州510600 [3]广东省电力集团公司,广东广州510600

出  处:《广东电力》2001年第1期23-25,共3页Guangdong Electric Power

摘  要:湛江发电厂 4号机在调试期间进行抗燃油泵的首次试运 ,发现B ,C泵振动大 ,停泵进行解体检查 ,复测轴的晃动度 ,找平衡后再次试转 ,振动仍无改善。技术人员对抗燃油泵进行了振动测试和分析 ,得出此振动属于拍振的结论。针对拍振的产生原因 ,提出可采取更换马达使两泵转速相同和在两泵间构筑隔离带等措施来解决此振动问题。During the commissioning of Unit 4 in Zhanjiang Power Plant, the vibration of its fire resistant oil pumps (also EH oil pumps) B, C was at high level at the first start. There was still no improvement after reassembling, run out checking and balancing. Consequently, the vibration was investigated and found to be beat vibration. In light of the cause of beat vibration, it is suggested that the motor be replaced to synchronize the two pumps, and that isolation zone be built between them.

关 键 词:抗燃油泵 拍振 刚度 振动测试 汽轮机 发电厂 

分 类 号:TK268.1[动力工程及工程热物理—动力机械及工程] TM621.3[电气工程—电力系统及自动化]

 