储能装置投入对整流发电机突加负载时瞬时电压的影响  被引量:1

Influence of Energy Storage Device on Instantaneous Voltage of Rectifier Generator with Suddenly-applied Load

在线阅读下载全文

作  者:肖晗 叶志浩[1] 纪锋[2] 颜清松 XIAO Han;YE Zhihao;JI Feng;YAN Qingsong(Naval University of Engineering,National Key Laboratory of Science and Technology on Vessel Integrated Power System;Naval University of Engineering,College of Electrical Engineering,Wuhan 430033,China)

机构地区:[1]海军工程大学电气工程学院,武汉430033 [2]海军工程大学舰船综合电力技术国防科技重点实验室,武汉430033

出  处:《船舶工程》2018年第12期35-40,共6页Ship Engineering

基  金:国家自然科学基金资助项目(51377167;51607185);973计划资助项目(613294)

摘  要:为了定量确定整流发电机突加负载时的瞬时电压变化与储能补偿功率之间的关系,提出一种基于负载等效和曲线拟合的瞬时电压计算方法。该方法通过将整流发电机直流侧的突加负载折算到交流侧,并利用整流桥的电压特性,分别给出空载突加和带载突加时的瞬时电压表达式;然后,将储能装置的投入等效为负电阻的形式进行功率补偿,通过计算得到瞬时电压与补偿功率之间的关系;最后,根据PSCAD仿真结果对理论计算进行曲线拟合,得到调整后的瞬时电压与补偿功率之间的关系,为下一步储能装置的优化配置提供理论依据。To quantitatively determine the relationship between instantaneous voltage and energy storage power of rectifier generator,a transient voltage calculation method based on load equivalence and curve fitting is proposed.DC-side load of rectifier generator converted to A C-side,and with the voltage characteristics of the rectifier bridge exploited,instantaneous voltage are given respectively under sudden-added situations of no-load and with load.Then function of energy storage device was equivalent to negative resistance in the form of power compensation,the relationship between the instantaneous voltage and power compensation could be derived by calculation.Finally,on the basis of theoretical calculation,the relationship between the adjusted instantaneous voltage and power compensation could be obtained by curve fitting for PSCAD simulation results.It provides a theoretical basis for the optimal allocation of energy storage.

关 键 词:储能装置 整流发电机 突加负载 瞬时电压 曲线拟合 储能补偿功率 

分 类 号:U665.12[交通运输工程—船舶及航道工程] TM74[交通运输工程—船舶与海洋工程]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象