角膜非球面切削术的基质预留量对角膜形态稳定性的影响  

Investigate the Effect of Different Corneal Matrix Reservation of Aspheric LASIK on Corneal Morphology Stability

在线阅读下载全文

作  者:陈章明[1] 赵婷婷[1] 黄丹[1] 

机构地区:[1]哈尔滨242医院眼科,黑龙江哈尔滨150066

出  处:《航空航天医学杂志》2014年第8期1067-1069,共3页Journal of Aerospace medicine

摘  要:目的观察非球面切削准分子激光原位角膜磨镶术(非球面LASIK)及准分子激光原位角膜磨镶术(普通LASIK)术后患者的临床疗效,探讨角膜非球面切削术的基质预留量对角膜形态稳定性的影响,为临床非球面LASIK预留安全的角膜基质厚度提供理论依据。方法按照患者意愿将患者分为非球面LASIK和普通LASIK两组,每组再按照预留基质多少分为350μm以上、300~350μm及280~299μm三组。不同术式两组术前各项指标均相似,差异无统计学意义。利用博士伦Orbscan II检测术后1周,1个月,1年,3年及5年角膜前曲率及Q值。主要指标统计非球面LASIK与普通LASIK术后第1周,1个月,1年,3年及5年进行复查各组的角膜前曲率及Q值等变化。结果非球面LASIK比普通LASIK术后Q值的变化更小。眼球的角膜曲率变化在两种术式的术后三年检查中均没有显著差异。两组均未发现屈光回退及圆锥角膜的发生。结论与普通LASIK相比,非球面LASIK能保持更好的角膜非球面形态。两组术式在预留基质280μm以上时,均是安全的。Objective To compare the visual effects of Q -guided aspheric transition zone Laser in situ keratomileu-sis ( Q-LASIK) versus conventional Laser in situ keratomileusis ( LASIK) and investigate the effect of different corneal matrix reservation of aspheric LASIK on corneal morphology stability.Evaluate the clinical effects of the two methods′postoperative treatment in different corneal matrix reservation in order to provide data for clinical operation .Methods According to the corneal matrix reservation , each group were divided into three subgroups (>350 μm、300~350 μm and 280~299μm).Q-value and anterior cornea curvatures was measured with Orbscan II topography system before and 1 week,1 month,6month,1 year, 3 year after surgery.The results of measurement in different time points were com-pared.Main Outcome Measures The Q -value and anterior cornea curvatures′changing were studied.Results All of operations were successful without severe complication after 3 years′follow-up.The changing of Q -value of Q-LASIK group were better compared to the tradition group after the surgery.And there was no significant difference in term of postoperative posterior cornea curvatures′changing between the two groups.Conclusions Q-guided aspheric profile and conventional LAS IK were safe and efficient for the correction of myopia.Moreover , Q-guided aspheric profile LAS IK induced a smaller changing of Q -value.when the corneal matrix reservation was greater than 280μm, both of the two surgery are safe.

关 键 词:准分子激光原位角膜磨镶术 非球面 Q值 角膜曲率 

分 类 号:R779.6[医药卫生—眼科]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象