检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:Daniel J.Liput Eleftheria Tsakalozou Dana C.Hammell Kalpana S.Paudel Kimberly Nixon Audra L.Stinchcomb
机构地区:[1]Department of Pharmaceutical Sciences,College of Pharmacy,University of Kentucky,Lexington,KY 40536,USA [2]AllTranz,Lexington,KY 40505,USA [3]Department of Pharmaceutical Sciences,College of Pharmacy,South College,Knoxville,TN 37922,USA [4]Department of Pharmaceutical Sciences,School of Pharmacy,University of Maryland,Baltimore,MD 21201,USA
出 处:《Journal of Pharmaceutical Analysis》2014年第4期234-241,共8页药物分析学报(英文版)
基 金:supported by funding from the National Institute ofAlcohol Abuse and Alcoholism AA016959(KN),AA016499(KN)and AA019853(DJL)and the Kentucky Science andTechnology Corporation(KSTC-184-512-07-029;ALS)
摘 要:Reported concentrations for endocannabinoids and related lipids in biological tissues can vary greatly; therefore, methods used to quantify these compounds need to be validated. This report describes a method to quantify anandamide (AEA), oleoylethanolamide (OEA) and palmitoylethanolamide (PEA) from rodent brain tissue. Analytes were exwacted using acetonitfile without further sample clean up, resolved on a C 18 reverse-phase column using a gradient mobile phase and detected using eleclmspmy ionization in positive selected ion monitoring mode on a single quadrupole mass spectrometer. The method produced high recovery rates for AEA, OEA and PEA, ranging from 98.1% to 106.2%, 98.5% to 102.2% and 85.4% to 89.5%, respectively. The method resulted in adequate sensitivity with a lower limit of quantification for AEA, OEAReported concentrations for endocannabinoids and related lipids in biological tissues can vary greatly; therefore, methods used to quantify these compounds need to be validated. This report describes a method to quantify anandamide (AEA), oleoylethanolamide (OEA) and palmitoylethanolamide (PEA) from rodent brain tissue. Analytes were exwacted using acetonitfile without further sample clean up, resolved on a C 18 reverse-phase column using a gradient mobile phase and detected using eleclmspmy ionization in positive selected ion monitoring mode on a single quadrupole mass spectrometer. The method produced high recovery rates for AEA, OEA and PEA, ranging from 98.1% to 106.2%, 98.5% to 102.2% and 85.4% to 89.5%, respectively. The method resulted in adequate sensitivity with a lower limit of quantification for AEA, OEA
关 键 词:Endocarmabinoids Acylethanolamides ANANDAMIDE OEA PEA LC-MS
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.222