检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:郝瑞参[1] 李德才[2] 刘华刚[1] 龚雯[1]
机构地区:[1]北京电子科技职业学院机械工程学院,北京100176 [2]北京交通大学机械与电子控制工程学院,北京100044
出 处:《仪表技术与传感器》2014年第8期16-17,29,共3页Instrument Technique and Sensor
基 金:北京市教委面上项目(KM201410858001);北京电子科技职业学院博士基金课题(YZKB2012001)
摘 要:利用化学共沉淀法制备了4种不同参数的磁流体,并对磁流体性能进行研究。将磁性液体用于压差传感器性能测试试验,分3组试验分别测量磁流体的密度、黏度和磁化强度对传感器的输出性能的影响,得出压差传感器灵敏度与磁流体的密度和磁化强度之间在一定范围内为线性关系,随着密度和磁化强度的增大,曲线逐渐趋于平缓,而传感器的响应时间也随着磁流体黏度的增大而增大的结论。Four different kinds of ferrofluid, which were applied into the experiment of differential pressure sensor, were pre- paled by chemical co-precipitation method. The density, viscosity and magnetization intensity of ferrofluid were analyzed and the in- fluence of the parameters on the differential pressure sensor were measured in experiments which were designed to verify the theory analysis. The relation between the sensitivity of differential pressure sensor and the density and magnetization of ferrofluid were lin- ear in a certain range. But with increasing of density and magnetization, the curve gradually leveled off when the ferrofluid was satu- rated. The sensor response time was lengthened with the increasing of viscosity of the ferrofluid.
分 类 号:TP212[自动化与计算机技术—检测技术与自动化装置]