种植体直径-长度比的三维有限元应力分析  被引量:10

Finite Element Analysis of Different Diameter to Length Ratio in Dental Implants

在线阅读下载全文

作  者:高健[1,2] 赵守亮[1] 周成杰[3] 

机构地区:[1]同济大学口腔医学院牙体牙髓教研室,口腔生物医学及转化医学实验室,上海200072 [2]天津医科大学口腔医院牙体牙髓科,天津300070 [3]同济大学土木工程学院,上海200092

出  处:《口腔颌面外科杂志》2014年第5期364-369,共6页Journal of Oral and Maxillofacial Surgery

摘  要:目的:探讨直径与长度连续变化时选择种植体尺寸的方法。方法 :运用Pro/E和ANSYS软件建立不同长度(7~16 mm)、不同直径(3~6 mm)的三维有限元模型,施加垂直荷载和侧向荷载,观察种植体位移峰值和骨组织VonMises应力峰值等评估指标。结果:垂直或侧向荷载作用下,随着直径和长度的增大,各评估指标均明显下降(60%~80%),相关度分析显示,两种荷载下直径的影响均较大(约90%),长度的影响与荷载有关(垂直荷载:18%~60%;侧向荷载:<7%)。直径-长度比兼顾种植体直径与长度,当确定皮质骨承载力及安全系数,便可由直径-长度关系曲线选择合适的种植体直径与长度。结论:种植体直径与长度均可明显影响种植体位移和骨组织应力峰值。本文介绍的直径长度比法可为临床医生选择、优化种植体提供一种新的思路。Objective: The aim of this study was to discuss the methodology of selecting implant with continuous changes of diameter and length. Methods: The Pro/engineering software was used to created 3-D models of dental implants with different diameters(3 mm^6 mm) and length(7 mm^16 mm), being assembled to 3-D models of mandible bone segments,which were imported into ANSYS finite element analysis software and meshed to create finite models. The values of dis-placement and Von-Mises stress of implant and bone were obtained, after models were loaded with vertical force and oblique load. Results: After models were loaded both by vertical and oblique loads, with the increase of implant diameter and length, the values of each evaluation indicators were significantly reduced(60%~80%). Effect of implant diameter was more significant(≈90%), the implant length was related to the types of loading(vertical force: 18%~60%; oblique load: 7%). The ratio construed by diameter and length was used for the selection of dental implants when safety factor was de-termined. Conclusion: Increasing the implant diameter and length can significantly reduce the displacement of implant and stress of bone tissue. Introduction of methodology of diameter-length ratio establishes a new practical and effective method for implants selection in clinical practices.

关 键 词:种植体直径 种植体长度 直径长度比 相关度 有限元分析 

分 类 号:R783.6[医药卫生—口腔医学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象