机构地区:[1]东南大学土木工程学院,江苏南京210096 [2]苏州工业园区设计研究院股份有限公司,江苏苏州215021
出 处:《施工技术》2014年第22期33-36,共4页Construction Technology
基 金:"十二五"国家科技支撑计划项目(2011BAJ10B03)
摘 要:在多种形式的预制叠合楼板基础上,提出一种带钢筋桁架翼缘板加劲的新型预应力叠合楼板;在施工工况下,对其进行了跨中有支撑和无支撑两种情况的静力加载试验研究,并分析了其施工阶段的刚度。结果表明,预制底板在有支撑和无支撑情况下均未开裂,且挠度均满足规范要求,为保证安全性,该新型预制底板短期刚度计算折减系数为0.75。A new kind of prestressed composite slab with steel truss flange ribbed panels was developed on the basis of various existing types of precast composite slab; two static loading experiments of this slab with or without support in the mid span respectively were conducted, and the stiffness under construction condition was analyzed. Results revealed that the new?type slab didn ’ t produce any cracks no matter whether it was supported and displacements were satisfied. For ensuring safety, the reduction coefficient of short?term rigidity of the precast bottom board was suggested to be 0?75 .
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:3.135.63.86