30年光伏组件再应用性能评估  

Evaluation of the Performance of 30-Year-Old PV Modules

在线阅读下载全文

作  者:王宏磊[1] 金叶义 陈荣荣[1] 董娴[2] 沈辉[1,2] 

机构地区:[1]中山大学太阳能研究所,广东省光伏技术重点实验室,广东广州510006 [2]顺德中山大学太阳能研究院,广东省光伏技术重点实验室,广东佛山528300

出  处:《顺德职业技术学院学报》2015年第1期18-21,共4页Journal of Shunde Polytechnic

摘  要:晶体硅光伏组件在户外长期运行时,各种材料会出现性能衰退。通过探究一批使用约30年的多晶硅组件,发现其在户外使用28年后衰减率仅为5.37%。此外,通过长期监测组件发电性能研究其在广州地区的发电和衰减情况,并采用EL测试研究材料衰变对组件影响,评估光伏组件的可靠性。When operating outdoors over a lengthy period of time, performance degradation of materials of silicon PV modules would occur. The authors of this paper studied a batch of approximately 30-year-old polycrystalline silicon modules and found that the power degradation is only about 5.37%after 28 years outdoor operation. In addition, these modules were being monitored to study their electricity yield and power degradation in Guangzhou city, and the EL tes-ter was used to detect these modules' defects in order to find out the influence of material degradation towards module performance and evaluate the reliability of PV modules.

关 键 词:光伏组件 多晶硅 质保期限 可靠性 

分 类 号:TM615[电气工程—电力系统及自动化]

 