MEMS微型惯性测量组合的标定  被引量:8

Resarch on Calibration Method for MEMS Micro Inertial Measurement Unit

在线阅读下载全文

作  者:陈湾湾[1,2] 陈智刚[1] 付建平[1] 

机构地区:[1]中北大学,地下目标毁伤技术国防重点学科实验室,山西太原030051 [2]清华大学精密仪器系,北京100084

出  处:《仪表技术与传感器》2014年第12期36-38,41,共4页Instrument Technique and Sensor

摘  要:由于MEMS器件的特殊性,在使用前必须进行标定。在MEMS器件误差数学模型的基础上,根据MEMS微惯性组合的十二位置标定方法,标定MIMU加速度计和陀螺仪的零偏稳定性和安装误差角,并将该方法应用于某MIMU的实验室标定中,验证了该标定方法的可行性。根据实验结果,对加速度计和陀螺仪的输出进行快速补偿,能进一步提高MIMU的姿态解算和导航精度。The MEMS devices must be calibrated before use because of its particularity. In order to calibrate MIMU accelerom- eter,gyroscope bias stability and angular misalignment, a calibration method for MIMU based on the error mathematical models of MIMU was designed. And this method was applied to a MIMU laboratory calibration,which verified the feasibility of the calibration method. According to the experimental results, making fast compensation for the accelerometer and the output of gyro can further improve the accuracy of MIMU attitude solution and navigation .

关 键 词:微惯性测量组合(MIMU) 标定 零偏 交叉耦合系数 安装误差角 

分 类 号:V249.3[航空宇航科学与技术—飞行器设计]

 