RGPCL对圆锥角膜前表面形态的影响  被引量:3

The effects of wearing RGPCL on anterior surface morphology in keratoconus

在线阅读下载全文

作  者:崔静[1] 胡琦[1] 黄磊[1] 刘明珠[1] 李雪[1] 王珂萌[1] 

机构地区:[1]哈尔滨医科大学附属第一医院眼科视光学中心,150001

出  处:《中华眼视光学与视觉科学杂志》2015年第1期27-30,共4页Chinese Journal Of Optometry Ophthalmology And Visual Science

摘  要:目的 观察RGPCL对圆锥角膜患者的视力及角膜前表面形态的影响.方法 回顾性病例对照研究.Pentacam眼前节分析系统分期为KK2期的圆锥角膜眼,有效配戴RGPCL者22例(28眼)作为实验组,无效配戴RGPCL者8例(9眼)作为对照组,均为理想或可接受的三点接触的配适状态.观察配戴RGPCL 1年后的矫正视力及配戴前后角膜前表面形态学参数的变化.采用配对t检验进行数据分析.结果 配戴RGPCL 1年后患者矫正视力提高,明显优于框架眼镜.与对照组相比,角膜前表面曲率平坦K值变化不大(P>0.05),而陡峭K值明显变小(t=4.420,P<0.01),角膜散光变小(t=4.271,P<0.01),形态学参数中表面变异指数(ISV)、高度不对称性指数(IHA)变小(t=2.939,P<0.01;t=1.690,P<0.05),最小曲率半径(Rmin)变大(t=2.315,P<0.05),圆锥角膜指数(KI)、中央圆锥角膜指数(CKI)、IVA、高度离心指数(IHD)差异无统计学意义(P>0.05).所有患眼随诊期都无严重并发症出现.结论 配戴RGPCL对KK2期圆锥角膜眼不但可提高视力而且能改善病变区角膜形态,是目前非手术方法矫治圆锥角膜的安全有效方法。Objective To investigate the effects of wearing RGPCL on visual acuity and anterior surface morphology in keratoconus.Methods Patients diagnosed with keratoconus in the KK2 stage using Pentacam software were recruited for a retrospective,comparative case series study.Twenty-two patients (28 eyes) who were prescribed RGPCL were included in the lens-wearing group.Eight patients (9 eyes) who wore glasses and seldom wore RGPCL were included in the control group.Subjects were fitted using the three-point-touch fitting method.The mean follow-up period was 12 months.Visual acuity was evaluated for both groups.The changes in the morphologic parameters on the anterior corneal surface were measured with Pentacam for comparisons between the lens-wearing and control groups.Data were analyzed with a paired t test.Results Corrected visual acuity improved after wearing RGPCLs,and the improvement was significantly better than for those who wore glasses.The Pentacam study showed there was a statistically significant flattening of the steep simulated keratometry (t=4.420,P〈0.01) compared to the control group.Although there was no significant difference in the flattest simulated keratometry after RGPCL wear (P〉0.05),corneal astigmatism decreased (t=4.271,P〈0.01).A significant reduction was found in the morphological parameters of ISV and IHA (t=2.939,P〈0.01; t=1.690,P〈0.05),while Rmin increased (t=2.315,P〈0.05).KI,CKI,IVA,IHD were not significantly different after RGPCL wear (P〉0.05).No serious eye complications were observed during the follow-up period.Conclusion Proper RGPCL fitting improves visual acuity and reshapes the ocular surface.These lenses are an effective and safe non-surgical treatment for keratoconus patients.

关 键 词:圆锥角膜 接触镜 硬性透气性 形态学参数 

分 类 号:R772.2[医药卫生—眼科]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象