哺乳动物离体心脏灌流技术与仪器设备  被引量:1

Mammalian heart perfusion in vitro technology and equipment

在线阅读下载全文

作  者:张碧鱼[1] 徐嘉雯[1] 陈笑霞[1] 龙天澄[1] 

机构地区:[1]中山大学生命科学学院,广东广州510275

出  处:《实验室科学》2015年第2期172-175,共4页Laboratory Science

摘  要:哺乳动物离体心脏主动脉逆行灌流法(Langendorff法),至今仍然是心血管研究领域中的一项重要技术方法,其内容也逐渐扩展到与心血管系统关联的转基因小鼠模型上。Langendorff法有恒压与恒流两种基本的灌流方式。两种方式各有优缺点和应用范围,实验装置也有所不同。近年来出现的新型仪器技术与设备装置,通过对蠕动泵的精确的反馈控制,将恒压与恒流灌流方式结合起来,并可适时进行转换和动态监测。采用新的仪器技术,只要严格控制实验条件,可大大提高实验效率,使离体心脏灌流法在研究和教学领域得到进一步的发展。Langendorff method is still an method, which is cardiac aortic retrograd method is also gradually applied to dorff method has two basic ways of important technology in the field of cardiovascular research e perfusion method in mammals isolated heart. Langendorff cardiovascular system of genetically modified mice model. Langenperfusion, constant voltage and constant current. Two ways has its advantages and disadvantages and application scope, the experimental device is also different. In recent years new equipment can provide with constant voltage perfusion and constant current perfusion through the peristaltic pump accurate feedback control, and can timely transformation and dynamic monitoring. The new instrument technology can greatly improve the efficiency of the experiment; make isolated heart perfusion method to obtain further development in the field of research and teaching, as long as we strictly control the experimental conditions.

关 键 词:LANGENDORFF 离体心脏灌流 恒压/恒流 反馈控制 蠕动泵 

分 类 号:Q4-33[生物学—生理学]

 