Four-sample lactose hydrogen breath test for diagnosis of lactose malabsorption in irritable bowel syndrome patients with diarrhea  被引量:4

Four-sample lactose hydrogen breath test for diagnosis of lactose malabsorption in irritable bowel syndrome patients with diarrhea

在线阅读下载全文

作  者:Jian-Feng Yang Mark Fox Hua Chu Xia Zheng Yan-Qin Long Daniel Pohl Michael Fried Ning Dai 

机构地区:[1]Department of Gastroenterology, The First People’s Hospital of Hangzhou [2]Department of Gastroenterology, Sir Run Run Shaw Hospital affiliated to College of Medicine, Zhejiang University [3]Division of Gastroen- terology and Hepatology, University Hospital Zürich [4]NIHR Nottingham Digestive Diseases Biomedical Research Unit, Queen’s Medical Centre

出  处:《World Journal of Gastroenterology》2015年第24期7563-7570,共8页世界胃肠病学杂志(英文版)

基  金:Supported by Nestle Research International and The Science and Technology Department of Zhejiang Province,No.2009C14016

摘  要:AIM: To validate 4-sample lactose hydrogen breath testing(4SLHBT) compared to standard 13-sample LHBT in the clinical setting.METHODS: Irritable bowel syndrome patients with diarrhea(IBS-D) and healthy volunteers(HVs) were enrolled and received a 10 g, 20 g, or 40 g doselactose hydrogen breath test(LHBT) in a randomized, double-blinded, controlled trial. The lactase gene promoter region was sequenced. Breath samples and symptoms were acquired at baseline and every 15 min for 3 h(13 measurements). The detection rates of lactose malabsorption(LM) and lactose intolerance(LI) for a 4SLHBT that acquired four measurements at 0, 90, 120, and 180 min from the same data set were compared with the results of standard LHBT.RESULTS: Sixty IBS-D patients and 60 HVs were studied. The genotype in all participants was C/C-13910. LM and LI detection rates increased with lactose dose from 10 g, 20 g to 40 g in both groups(P < 0.001). 4SLHBT showed excellent diagnostic concordance with standard LHBT(97%-100%, Kappa 0.815-0.942) with high sensitivity(90%-100%) and specificity(100%) at all three lactose doses in both groups.CONCLUSION: Reducing the number of measurements from 13 to 4 samples did not significantly impact on the accuracy of LHBT in health and IBS-D. 4SLHBT is a valid test for assessment of LM and LI in clinical practice.AIM: To validate 4-sample lactose hydrogen breath testing(4SLHBT) compared to standard 13-sample LHBT in the clinical setting.METHODS: Irritable bowel syndrome patients with diarrhea(IBS-D) and healthy volunteers(HVs) were enrolled and received a 10 g, 20 g, or 40 g doselactose hydrogen breath test(LHBT) in a randomized, double-blinded, controlled trial. The lactase gene promoter region was sequenced. Breath samples and symptoms were acquired at baseline and every 15 min for 3 h(13 measurements). The detection rates of lactose malabsorption(LM) and lactose intolerance(LI) for a 4SLHBT that acquired four measurements at 0, 90, 120, and 180 min from the same data set were compared with the results of standard LHBT.RESULTS: Sixty IBS-D patients and 60 HVs were studied. The genotype in all participants was C/C-13910. LM and LI detection rates increased with lactose dose from 10 g, 20 g to 40 g in both groups(P < 0.001). 4SLHBT showed excellent diagnostic concordance with standard LHBT(97%-100%, Kappa 0.815-0.942) with high sensitivity(90%-100%) and specificity(100%) at all three lactose doses in both groups.CONCLUSION: Reducing the number of measurements from 13 to 4 samples did not significantly impact on the accuracy of LHBT in health and IBS-D. 4SLHBT is a valid test for assessment of LM and LI in clinical practice.

关 键 词:LACTOSE hydrogen BREATH test DIAGNOSIS LACTOSE MALABSORPTION LACTOSE INTOLERANCE Irritablebowel syndrome 

分 类 号:R574.4[医药卫生—消化系统]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象