出 处:《Chinese Physics B》2015年第10期200-212,共13页中国物理B(英文版)
基 金:Project supported by the China National Funds for Distinguished Young Scientists of National Natural Science Foundation of China(Grant No.51025622);the National Natural Science Foundation of China(Grant No.51406095);the 100 Top Talents Program of Tsinghua University,Beijing,China(2011)
摘 要:In order to improve the reconstruction performance for ill-posed emission tomographic problems with limited projections, a generalized interpolation method is proposed in this paper, in which the virtual lines of projection are fabricated from, but not linearly dependent on, the measured projections. The method is called the virtual projection(VP) method.Also, an iterative correction method for the integral lengths is proposed to reduce the error brought about by the virtual lines of projection. The combination of the two methods is called the iterative virtual projection(IVP) method. Based on a scheme of equilateral triangle plane meshes and a six asymmetrically arranged detection system, numerical simulations and experimental verification are conducted. Simulation results obtained by using a non-negative linear least squares method,without any other constraints or regularization, demonstrate that the VP method can gradually reduce the reconstruction error and converges to the desired one by fabricating additional effective projections. When the mean square deviation of normal error superimposed on the simulated measured projections is smaller than 0.03, i.e., the signal-to-noise ratio(SNR)for the measured projections is higher than 30.4, the IVP method can further reduce the reconstruction error reached by the VP method apparently. In addition, as the regularization matrix in the Tikhonov regularization method is updated by an iterative correction process similar to the IVP method presented in this paper, or the Tikhonov regularization method is used in the IVP method, good improvement is achieved.In order to improve the reconstruction performance for ill-posed emission tomographic problems with limited projections, a generalized interpolation method is proposed in this paper, in which the virtual lines of projection are fabricated from, but not linearly dependent on, the measured projections. The method is called the virtual projection(VP) method.Also, an iterative correction method for the integral lengths is proposed to reduce the error brought about by the virtual lines of projection. The combination of the two methods is called the iterative virtual projection(IVP) method. Based on a scheme of equilateral triangle plane meshes and a six asymmetrically arranged detection system, numerical simulations and experimental verification are conducted. Simulation results obtained by using a non-negative linear least squares method,without any other constraints or regularization, demonstrate that the VP method can gradually reduce the reconstruction error and converges to the desired one by fabricating additional effective projections. When the mean square deviation of normal error superimposed on the simulated measured projections is smaller than 0.03, i.e., the signal-to-noise ratio(SNR)for the measured projections is higher than 30.4, the IVP method can further reduce the reconstruction error reached by the VP method apparently. In addition, as the regularization matrix in the Tikhonov regularization method is updated by an iterative correction process similar to the IVP method presented in this paper, or the Tikhonov regularization method is used in the IVP method, good improvement is achieved.
关 键 词:ill-posed problem emission tomography limited projections Tikhonov regularization
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...