活性炭纤维覆膜电极高电压电吸附处理含盐废水  被引量:2

Salt-containing wastewater treatment by high-voltage capacitive adsorption of activated carbon fiber electrode insulated by organic film

在线阅读下载全文

作  者:韩丹[1] 徐有林[1] 赵贤广[1] 任朋[1] 徐炎华[1] 

机构地区:[1]南京工业大学环境学院,江苏南京210009

出  处:《工业水处理》2015年第10期20-23,共4页Industrial Water Treatment

基  金:国家太湖水专项基金项目(20082X07101-003)

摘  要:针对电容吸附除盐法中电压低、处理效率低、电极易腐蚀等缺点,对活性炭纤维电极表面进行了覆膜绝缘处理。Na Cl模拟溶液实验结果表明,覆膜电极电吸附除盐的最佳操作电压为20 V,最佳作用时间为30 min。对低浓度Na Cl溶液(<300 mg/L),溶液电导率去除率可达80%以上。吸附等温线拟合结果表明,低电压(<10 V)时,吸附倾向于Langmuir模型;高电压时,吸附更加符合Freundlich模型。Aiming at the disadvantages of capacitive adsorption desalination process,such as low voltage,low treat-ment efficiency,easily corrosive electrode,etc.,the surface of activated carbon fiber electrode has been treated by membrane-coated insulation. The results from NaCl simulated solution experiment shows that in the membrane-coated electrode electro-adsorption desalination process,the optimal operation voltage is 20 V,and optimal reaction time 30 min. When the low-concentration NaCl solution is less than 300 mg/L,the electrical conductivity removing rate of the solution are above 80%. The result of electro-adsorption isotherm fitting shows that when the low voltage is less than 10 V,the adsorption tends to Langmuir model. When the voltage is high, the adsorption is in accordance with Freundlich model.

关 键 词:电容吸附 活性炭纤维电极 绝缘膜 高电压 除盐 

分 类 号:X703.1[环境科学与工程—环境工程]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象