锥形束CT联合微动力系统拔除儿童Ⅲ型多生牙  被引量:11

Combination of Cone-beam CT and Micro Power System to Extract TypeⅢ Impacted Supernumerary Teeth for Children

在线阅读下载全文

作  者:张智勇[1] 张晓[1] 孟甜[1] 高巍[1] 陈全[1] 刘文曙[1] 陈宇寰 

机构地区:[1]北京大学口腔医院门诊部外科,北京100034

出  处:《口腔医学研究》2015年第12期1244-1246,共3页Journal of Oral Science Research

摘  要:目的:探讨锥形束CT与微动力系统联合用于儿童Ⅲ型多生牙拔除的临床效果。方法:回顾锥形束CT定位,微动力系统拔除儿童Ⅲ型多生牙病例。结果:CBCT定位与临床手术所见符合率为100%,平均手术时间(27.5±6.1)min,疼痛Wong-Baker评分为术后即刻(3.9±1.2)以及术后7d(1.3±1.1)。病例愈合良好。结论:CBCT和微动力系统在儿童Ⅲ型埋伏多生牙的拔除中可以有效减少手术时间,降低创伤和其他并发症。Objective:To investigate the clinical outcomes of combined application of Cone-beam CT(CBCT)and micro power system for extraction of type Ⅲ impacted supernumerary teeth for children.Methods:Children with typeⅢimpacted supernumerary teeth who accepted the tooth extraction by CBCT and micro power system(implantology surgical unit)were collected.The accordance between CBCT and operation finding was analysed.The average operation time,post-operation pain and the complications of extraction were recorded.Results:The accordance was 100% between CBCT and operation finding.The average operation time was(27.5±6.1)min.Average Wong-Baker score for post-operative pain was(3.9±1.2)immediately after extraction and(1.3±1.1)7days after extraction.All wounds healed well without any complications.Conclusion:Combined application of CBCT and micro power system can reduce operation time to extract type Ⅲ impacted supernumerary teeth for children and reduce complications.

关 键 词:锥形束CT 种植机 多生牙 

分 类 号:R782.11[医药卫生—口腔医学]

 