检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:苏梓铭[1] 刘凯[1] 刘庭[1] 肖宾[1] 彭勇[1] 唐盼[1] 吴田[1]
出 处:《电力科学与技术学报》2015年第4期141-148,共8页Journal of Electric Power Science And Technology
基 金:南方电网公司科技项目(K-GZM2014-007)
摘 要:10kV同杆多回线路中间相导线检修受到带电作业安全距离等因素的影响,难以开展带电作业,影响了城市供电可靠性。针对10kV同塔多回线路特点,仿真计算得出多回线路发生短路时产生的过电压,明确带电作业工具性能要求;采用理论分析与试验研究相结合的方法,研制10kV同塔多回线路特殊相导线提线工具。通过进行10kV同杆多回线路特殊相导线带电作业方法及其工器具的研究,实现10kV同塔多回线路带电作业,提高了线路供电可靠性。Special conductor maintenance on ed by safe distance for live working, which 10 kV multi-circuit lines on the same tower are affectreduces the power supply reliability in cities. According to the characteristics of 10 kV multi-circuit lines on the same tower, short circuit caused overvoltage in multi-circuit lines were simulated, performance requirements of live working tools were also proposed clearly. Based on theoretical analysis and experimental researching, the Hanging special conductor tools for live-working on 10 kV multi-circuit lines were developed. With the Hanging Special conductor tools, the live working projects for 10 kV multi-circuit lines were carried out and the reliability of power supply was improved successfully.
关 键 词:10kV同杆多回线路 提线工具 带电作业 安全距离
分 类 号:TM755[电气工程—电力系统及自动化]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.28