冻融循环与氯离子侵蚀后预应力混凝土梁受弯性能  被引量:5

Flexural behaviors of prestressed concrete beams after freeze-thaw cycles and chloride penetration

在线阅读下载全文

作  者:葛文杰[1] 曹大富[1] 徐荣[1] 

机构地区:[1]扬州大学建筑科学与工程学院,江苏扬州225127

出  处:《南京理工大学学报》2015年第6期744-749,共6页Journal of Nanjing University of Science and Technology

基  金:国家自然科学基金(50978224;51278445;51308490;51278230);江苏省自然科学基金(BK20130450);住房和城乡建设部科学技术计划项目(2013-K4-17);江苏省高校自然科学基金(13KJB560015);扬州市科技计划项目(2012149)

摘  要:为研究预应力钢筋混凝土结构的耐久性,在预应力度分别为0.35、0.52和0.62的预应力混凝土梁试件分别经历50、75次冻融循环作用和氯离子溶液腐蚀后,对其进行静力受弯试验。研究表明:动弹性模量随冻融循环次数的增加下降较快,预应力度高的试件动弹性模量损失较小;预应力度分别为0.35、0.52和0.62的试件,在冻融循环75次后的开裂荷载较冻融循环50次的试件分别下降6.9%、6.7%、5.7%,极限荷载分别下降14.7%、17.5%、11.6%;冻融循环50次后,预应力度为0.52和0.62的试件较预应力度为0.35试件的开裂荷载分别高20%、17.85%,极限荷载分别高21.4%、8.7%;冻融循环75次后,预应力度为0.52和0.62的试件较预应力度为0.35试件的开裂荷载分别高23.8%、19.0%,极限荷载分别高24.1%、19.4%;氯离子侵蚀在短期内对试件极限承载力影响较小。In order to study the durability of prestressed concrete structures,6 prestressed concrete beams with partial prestressing ratios of 0. 35,0. 52 and 0. 62 are tested by static flexural experiments after experiencing freeze-thaw cycles and chloride penetration for 50 and 75 times. The results show that the concrete dynamic elastic modulus decrease fast with the increase of the freeze-thaw cycle number,and the dynamic elastic modulus of tested specimens with the high partial prestressing ratios decrease less; for components with prestressing ratios of 0. 35,0. 52 and 0. 62,comparing the results after 50 times freeze-thaw cycles with the results after 75 times freeze-thaw cycles,the cracking loads decrease 6. 9%,6. 7% and 5. 7% respectively and the ultimate loads decrease 4. 7%,17.5% and 11. 6% respectively; after 50 times freeze-thaw cycles,the cracking loads of components with prestressing ratios of 0. 52 and 0. 62 are higher than those of 0. 35 by 20%,17. 85% respectively,and the ultimate loads are higher by 21. 4%,8. 7% respectively; after 75 times freeze-thaw cycles,the cracking loads of components with prestressing ratios of 0. 52 and 0. 62 are higher than those of 0.35 by 23. 8%,19. 0% respectively,and the ultimate loads are higher by 24. 1%,19. 4% respectively;chloride penetration effects the bearing capacity of the components less.

关 键 词:冻融循环 氯离子侵蚀 预应力混凝土梁 受弯性能 静力受弯试验 动弹性模量 开裂荷载 极限荷载 

分 类 号:TU375.1[建筑科学—结构工程]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象