Comparison of Diaton transpalpebral tonometer with applanation tonometry in keratoconus  

Comparison of Diaton transpalpebral tonometer with applanation tonometry in keratoconus

在线阅读下载全文

作  者:Robert PL Wisse Natalie Peeters Saskia M Imhof Allegonda van der Lelij 

机构地区:[1]Utrecht Corneal Research Group Department of Ophthalmology, University Medical Center Utrecht, Utrecht 3508 GA, The Netherlands

出  处:《International Journal of Ophthalmology(English edition)》2016年第3期395-398,共4页国际眼科杂志(英文版)

摘  要:AIM: To Investigate the added value of using a Diaton transpalpebral tonometer (DT) to measure lOP in keretoconus. Most type of tonometers use corneal applanation or biomechanical resistance to measure intraocular pressure (lOP); however, these factors can be altered by keratoconus. Specifically, we examined whether DT can detect false-negative low Goldmann applanation tonometry (AT) measurements. METHODS: Patients with keratoconus were recruited from our tertiary academic treatment center. Measurements included AT and DT (in random order) and Scheimpflug imaging. An age- and gender-matched group of control subjects with no history of corneal disease or glaucoma was also recruited. RESULTS: In total, 130 eyes from 66 participants were assessed. In the keratoconus group, mean AT was 11.0± 2.6, mean DT 11±5.5 (P =0.729)and the two measures were correlated significantly(P=0.006, R=0.323). However, a Bland-Altman plot revealed a wide distribution and poor agreement between both measurements. Previous corneal crosslinking, corneal pachymetry, and Krumeich classification had no effect on measured IOP. CONCLUSION: Measurements obtained using a Diaton tonometer are not affected by corneal biomechanics; however, its poor agreement with Goldmann AT values calls into question the added value of using a Diaton tonometer to measure lOP in keratoconus.AIM: To Investigate the added value of using a Diaton transpalpebral tonometer (DT) to measure lOP in keretoconus. Most type of tonometers use corneal applanation or biomechanical resistance to measure intraocular pressure (lOP); however, these factors can be altered by keratoconus. Specifically, we examined whether DT can detect false-negative low Goldmann applanation tonometry (AT) measurements. METHODS: Patients with keratoconus were recruited from our tertiary academic treatment center. Measurements included AT and DT (in random order) and Scheimpflug imaging. An age- and gender-matched group of control subjects with no history of corneal disease or glaucoma was also recruited. RESULTS: In total, 130 eyes from 66 participants were assessed. In the keratoconus group, mean AT was 11.0± 2.6, mean DT 11±5.5 (P =0.729)and the two measures were correlated significantly(P=0.006, R=0.323). However, a Bland-Altman plot revealed a wide distribution and poor agreement between both measurements. Previous corneal crosslinking, corneal pachymetry, and Krumeich classification had no effect on measured IOP. CONCLUSION: Measurements obtained using a Diaton tonometer are not affected by corneal biomechanics; however, its poor agreement with Goldmann AT values calls into question the added value of using a Diaton tonometer to measure lOP in keratoconus.

关 键 词:Diaton Goldmann applanation tonometry transpalpebral tonometry KERATOCONUS Bland-Altman plot 

分 类 号:R770.426.2[医药卫生—眼科]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象