Elevated urine formaldehyde in elderly patients with primary open angle glaucoma  被引量:3

Elevated urine formaldehyde in elderly patients with primary open angle glaucoma

在线阅读下载全文

作  者:Ying Cui Tao Su Shao-Dan Zhang Ping Huang Ying-Ge He Ying Liu Chun Zhang Robert Ritch Rong-Qiao He 

机构地区:[1]Departrncnt of Ophthalmology, Peking University Third Hospital, Beijing 100191, China [2]Key Laboratory of Vision Loss and Restoration, Ministry of Education, Beijing 100191, China [3]State Key Laboratory of Brain and Cognitive Science,Institute of Biophysics, Chinese Academy of Sciences,Beijing 100101, China [4]Einhorn Clinical Research Center, New York Eye and Ear Infirmary of Mount Sinai, New York, NY 10003, USA

出  处:《International Journal of Ophthalmology(English edition)》2016年第3期411-416,共6页国际眼科杂志(英文版)

基  金:Supported by National Basic Research Program of China(973 Program,No.2012CB911004);the National Natural Science Foundation of China(No. 81041008;No.30772376)

摘  要:AIM:To investigate the risk factor of primary open angle glaucoma(POAG),which is the leading cause of irreversible blindness worldwide.An abnormally high level of endogenous formaldehyde(FA) has recently been found correlated with cell death and neurodegenerative disease,raising the possibility of a putative correlation of abnormal endogenous FA with POAG.· METHODS:Thirty-four elderly patients with POAG and sixteen healthy controls were enrolled.Glaucomatous visual defects were present at both the functional(visual field) and structural[retinal nerve fiber layer(RNFL)thickness]levels.Morning urine samples were obtained and were analyzed by high-performance liquid chromatography(HPLC) to detect the endogenous FA level in a double blind manner.· RESULTS:Patients with POAG(P 〈0.05) had significantly higher urine FA levels.The urine FA level of patients with severe visual field defects[mean deviation(MD)≥12 dB]was significantly(P〈0.001) greater than that of patients with mild to moderate defects(MD〈12 dB).By optical coherence tomography(OCT),the superior and inferior RNFL thickness of POAG group was significantly(P〈0.001) thinner than in controls.Furthermore,the superior and inferior thinning of the RNFL was correlated with the elevation of urine FA concentration.CONCLUSION:Endogenous FA level is positively correlated with the neuronal defects of POAG.AIM:To investigate the risk factor of primary open angle glaucoma(POAG),which is the leading cause of irreversible blindness worldwide.An abnormally high level of endogenous formaldehyde(FA) has recently been found correlated with cell death and neurodegenerative disease,raising the possibility of a putative correlation of abnormal endogenous FA with POAG.· METHODS:Thirty-four elderly patients with POAG and sixteen healthy controls were enrolled.Glaucomatous visual defects were present at both the functional(visual field) and structural[retinal nerve fiber layer(RNFL)thickness]levels.Morning urine samples were obtained and were analyzed by high-performance liquid chromatography(HPLC) to detect the endogenous FA level in a double blind manner.· RESULTS:Patients with POAG(P 〈0.05) had significantly higher urine FA levels.The urine FA level of patients with severe visual field defects[mean deviation(MD)≥12 dB]was significantly(P〈0.001) greater than that of patients with mild to moderate defects(MD〈12 dB).By optical coherence tomography(OCT),the superior and inferior RNFL thickness of POAG group was significantly(P〈0.001) thinner than in controls.Furthermore,the superior and inferior thinning of the RNFL was correlated with the elevation of urine FA concentration.CONCLUSION:Endogenous FA level is positively correlated with the neuronal defects of POAG.

关 键 词:primary open angle glaucoma urineformaldehyde Alzheimer's disease 

分 类 号:R775.2[医药卫生—眼科]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象