机构地区:[1]Department of Ophthalmology, Anhui Provincial Hospital,Anhui Medical University
出 处:《International Journal of Ophthalmology(English edition)》2016年第4期572-574,共3页国际眼科杂志(英文版)
基 金:Supported by the Natural Science Foundation of Anhui Province(No.1508085MH188);Science Foundation of Anhui Provincial health Bureau(No.13zc046)
摘 要:AIM: To observe the changes of vitreous cavity length and diopter after scleral encircling(SE) produce.·METHODS: This prospective study included 68 eyes of68 non-consecutive patients with macula-off retinal detachment who were operated by SE surgery. The corneal refractive power, ocular axial length and diopter were measured by keratometer, A-mode ultrasonic meter and computed dioptometer.· RESULTS: There was no significant difference in corneal refractive power among preoperative and post operative 1, 3 and 6mo(0.57±0.54 D at pre-surgery; 0.72±0.26 D at 1mo; 0.71 ±0.34 D at 3mo; 0.69 ±0.31 D at 6mo;all P 〉0.05). Axial lengths were obviously lengthened,especially in vitreous cavity length(17.87 ±3.09 mm,19.69 ±3.12 mm, 18.97 ±3.56 mm, 18.76 ±3.47 mm, 18.68 ±3.42 mm at pre-surgery, 1wk, 1, 3 and 6mo postoperatively,P 〈0.05) and diopter also increased at beginning and then recovered gradually. After 1 and 3 mo, axial length(vitreous cavity length) and myopia were more and in higher degree than before surgery.·CONCLUSION: The change of postoperative vitreous cavity length is the main factor that results in the changes of axial length and then makes the change of diopter.AIM: To observe the changes of vitreous cavity length and diopter after scleral encircling(SE) produce.·METHODS: This prospective study included 68 eyes of68 non-consecutive patients with macula-off retinal detachment who were operated by SE surgery. The corneal refractive power, ocular axial length and diopter were measured by keratometer, A-mode ultrasonic meter and computed dioptometer.· RESULTS: There was no significant difference in corneal refractive power among preoperative and post operative 1, 3 and 6mo(0.57±0.54 D at pre-surgery; 0.72±0.26 D at 1mo; 0.71 ±0.34 D at 3mo; 0.69 ±0.31 D at 6mo;all P 〉0.05). Axial lengths were obviously lengthened,especially in vitreous cavity length(17.87 ±3.09 mm,19.69 ±3.12 mm, 18.97 ±3.56 mm, 18.76 ±3.47 mm, 18.68 ±3.42 mm at pre-surgery, 1wk, 1, 3 and 6mo postoperatively,P 〈0.05) and diopter also increased at beginning and then recovered gradually. After 1 and 3 mo, axial length(vitreous cavity length) and myopia were more and in higher degree than before surgery.·CONCLUSION: The change of postoperative vitreous cavity length is the main factor that results in the changes of axial length and then makes the change of diopter.
关 键 词:sclera encircling vitreous cavity length diopter axial length
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...