溶氧电极新型搅拌装置的设计与实验  

Design of and Experiment on a New Stirring Device with Dissolved Oxygen Electrode

在线阅读下载全文

作  者:宋元明[1] 杨丽红[1] 杨高强 袁旭军 

机构地区:[1]上海理工大学机械工程学院,上海200093 [2]上海科源电子科技有限公司,上海201101

出  处:《电子科技》2016年第5期39-41,44,共4页Electronic Science and Technology

摘  要:膜式溶氧电极作为测量溶液中含氧量的一种重要测量工具,但因其电化学性质受到局限而需要搅拌,针对人工搅拌的不足,提出了将提高测量稳定性的一种由于BOD5动测量的新型溶氧电极搅拌装置,装置采用离心式机械搅拌。通过实验验证,该种搅拌方式有助于稳定测量出培养瓶内溶液的溶氧量。The membrane dissolved oxygen electrode is an important tool for measuring oxygen content in solution,but there is limitation because of its chemical properties as the dissolved oxygen electrode measurement of oxygen consumption usually requires artificial stirring. A new dissolved oxygen electrode stirring device using BOD5 automatic measurement is put forward to increase the stability by using the centrifugal type mechanical stirring. Experiments show that the proposed stirring device offers stable measurement of the dissolved oxygen content in the culture bottle.

关 键 词:BOD5分析 隔膜电极法 搅拌装置 

分 类 号:TN304[电子电信—物理电子学] TH122[机械工程—机械设计及理论]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象